DOI QR코드

DOI QR Code

Capacity and the moment-curvature relationship of high-strength concrete filled steel tube columns under eccentric loads

  • 투고 : 2006.08.02
  • 심사 : 2007.03.07
  • 발행 : 2007.04.25

초록

Recently, CFT column has been well-studied and reported on, because a CFT column has certain superior structural properties as well as good productivity, execution efficiency, and improved rigidity over existing columns. However, CFT column still has problems clearing the capacity evaluation between its steel tube member and high-strength concrete materials. Also, research on concrete has examined numerical values for high-strength concrete filled steel square tube columns (HCFT) to explain transformation performance (M-${\phi}$) when a short-column receives equal flexure-moment from axial stress. Moment-curvature formulas are proposed for HCFT columns based on analytic assumption described in this paper. This study investigated structural properties (capacity, curvature), through a series of experiments for HCFT with key parameters, such as strength of concrete mixed design (58.8 MPa), width-thickness ratio (D/t), buckling length to sectional width ratio (Lk/D) and concrete types (Zeolite, Fly-ash, Silica-fume) under eccentric loads. A comparative analysis executed for the AISC-LRFD, AIJ and Takanori Sato, etc. Design formulas to estimate the axial load (N)-moment (M)-curvature (${\phi}$) are proposed for HCFT columns based on tests results described in this paper.

키워드

과제정보

연구 과제 주관 기관 : Korea Research Foundation

참고문헌

  1. ACI Committee 318, (2005), Building code requirements for reinforcement concrete and commentary. American Concrete Institute: 119-124.
  2. AISC. (2005), Load and resistance factor design (LRFD) specification for structural steel buildings, Chicago IL: American Institute of Steel Construction, Inc: 77-83.
  3. Architectural Institute of Japan, (1997), Recommendations for design and construction of concrete filled steel tubular structures: 34-68.
  4. Architectural Institute of Japan, (1975), Recommendations for plasticity design of steel structures: 114-129.
  5. Architectural Institute of Japan, (1987), Standard for structural calculation of steel reinforced concrete structures.
  6. Architectural Institute of Korea (2004), Standard for design and construction of concrete filled steel tubular structures, Seoul Korea: 24-34.
  7. Campione G. and Scibilia N. (2002),"Beam-column behavior of concrete filled steel tubes", Steel Compos. Struct., 2(4): 259-276 https://doi.org/10.12989/scs.2002.2.4.259
  8. Eurocode 4(EC4, 1994), European Committee for Standardization (draft: Design of composite steel and concrete structures).
  9. Han, L.H. and Yao, G.H. (2003),"Influence of concrete compaction on the strength of concrete-filled steel RHS columns", J. Constr. Steel Res., 59(6), 751-767. https://doi.org/10.1016/S0143-974X(02)00076-7
  10. Inai, E., Mukai, A., Kai, M., Tokinoya, H., Fukumoto, T. and Mori, K. (2004),"Behavior of concrete-filled steel tube beam columns", ASCE February; 130(2), 189-202. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:2(189)
  11. Inoue, T., Fukumoto, T., Hayashi, N., and Okada, T. (1994),"Shear-flexural behavior of concrete filled steel tubular column using high-strength materials", Summary of Technical papers of Anneal Meeting of Architectural Institute of Japan, Structures II, Architectural Institute of Japan, Tokyo, 1994, 1599-1600.
  12. Itoh, S. and Yauzaki, C. (1992),"Studies on resistance and deformation capacities of concrete-filled with low YR high-tensile steel and high-strength concrete", Summary of Technical papers of Anneal Meeting of Architectural Institute of Japan, Structures II, Architectural Institute of Japan, Tokyo, 1801-1802.
  13. Knowles, R. B. and Park, R. (1969),"Strength of concrete filled steel tubular column", J. Struct. Div., ASCE; 95(ST12), 2565-87.
  14. Lee, S.J., Park, J.M., and Kim W.J. (2000),"Behavior properties of high-strength concrete filled steel tube columns", 3rd international symposium on architectural interchanges in Asia, AIA February: 923-934.
  15. Lee, S.J., Park, J.M., and Kim W.J. (1998),"A study on behaviors of high-performance concrete filled steel tube column using silica-fume", Pacific structural steel conference, PSSC October: 949-954.
  16. Liu, D., Gho, W. M. and Yuan, J. (2003),"Ultimate capacity of high-strength rectangular concrete-filled steel hollow section stub columns", J. Constr. Steel Res., 59(12), 1499-515. https://doi.org/10.1016/S0143-974X(03)00106-8
  17. Popovics s. (1973),"A numerical approach to the complete stress-strain curves for concrete", Cement and Concrete Res., 3(5), 583-599. https://doi.org/10.1016/0008-8846(73)90096-3
  18. Saito, Y., Yamaguchi, I., Matsutani, T., Kadono, A., and Matsumura, H. (1989),"A study on the behavior of concrete filled steel tubular columns", Part 1-6. Summary of Technical papers of Anneal Meeting of Architectural Institute of Japan, Structures II, Architectural Institute of Japan, Tokyo, 1613-1624.
  19. Sakino, K., Nakahara, H., Morino, S. and Nishiyama, I. (2004),"Behavior of centrally loaded concrete-filled steel-tube short columns", J. Struct. Eng., ASCE; 130(2), 180-188. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:2(180)
  20. Shams, M. and Saadeghvaziri, M. A. (1999),"Nonlinear response of concrete-filled steel tubular columns under axial loading", ACI Struct. J., 96(5), 1009-17.
  21. Takanori SATO. (1999),"Proposal of unified and simplified design method for concrete filled steel tube in short column to slender column", AIJ J. Struct. Constr. Eng., December, 526, 209-219.
  22. Tomii, M., Yashimaro, K. and Morishita, Y. (1977),"Experimental studies on concrete filled steel tubular stub columns under concentric loading", Proceedings of the International Colloquium on Stability of Structures under Static and Dynamic Loads. Washington; SSRC/ASCE: 718-41.
  23. Uy, B. (2003),"High-strength steel-concrete composite columns for buildings", Struct. Build., 156, 3-14. https://doi.org/10.1680/stbu.2003.156.1.3
  24. Varma, A. H., Ricles, J. M., Sause, R., Ream, A., Sause, R., and Lu, L. W. (2004),"Seismic behavior and design of high-strength square concrete-filled steel tube beam columns", J. Struct. Eng., ASCE February 2004, 130(2), 169-179. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:2(169)
  25. Young, B. and Lui, W. M. (2005),"Behavior of cold-formed high strength stainless steel sections", J. Struct. Eng., ASCE, 131(11), 1738-1745. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:11(1738)

피인용 문헌

  1. Influence of Slenderness on High-Strength Rectangular Concrete-Filled Tubular Columns with Axial Load and Nonconstant Bending Moment vol.138, pp.12, 2012, https://doi.org/10.1061/(ASCE)ST.1943-541X.0000590
  2. Effects of tendon damage on static and dynamic behavior of CFTA girder vol.15, pp.5, 2013, https://doi.org/10.12989/scs.2013.15.5.567
  3. A study on axial compressive behaviors of reinforced concrete filled tubular steel columns vol.76, 2012, https://doi.org/10.1016/j.jcsr.2012.03.023
  4. Axial compressive behaviour of circular CFFT: Experimental database and design-oriented model vol.21, pp.4, 2016, https://doi.org/10.12989/scs.2016.21.4.921
  5. Local Buckling of Axially Compressed Rectangular Concrete-Filled Steel Tubes vol.73, 2016, https://doi.org/10.1051/matecconf/20167304017
  6. Stability of rectangular concrete-filled steel tubes vol.106, 2017, https://doi.org/10.1051/matecconf/201710604003
  7. Performance Evaluation of Q690 High-Strength Concrete-Filled Thin-Walled Steel Tubular Columns under Compression-Bending Coupling vol.2018, pp.1563-5147, 2018, https://doi.org/10.1155/2018/8386741
  8. Tubular composite beam-columns of annular cross-sections and their design practice vol.10, pp.2, 2010, https://doi.org/10.12989/scs.2010.10.2.109
  9. Uni-axial behaviour of normal-strength CFDST columns with external steel rings vol.13, pp.6, 2007, https://doi.org/10.12989/scs.2012.13.6.587
  10. Uni-axial behaviour of normal-strength concrete-filled-steel-tube columns with external confinement vol.3, pp.6, 2012, https://doi.org/10.12989/eas.2012.3.6.889
  11. A constitutive model for confined concrete in composite structures vol.24, pp.6, 2017, https://doi.org/10.12989/scs.2017.24.6.689
  12. Local buckling of rectangular steel tubes filled with concrete vol.31, pp.2, 2007, https://doi.org/10.12989/scs.2019.31.2.201