Abstract
For large power applications, multi-stacked tape should be used because single tape is limited in flowing demanded current capacity. Besides insulation between layers is needed for safe operation because high voltages are generated in those applications. In this study, considering those situations which mentioned above, we measure the magnetization loss in several multi-stacked tape samples having the different insulation thicknesses and various packing numbers of tape by external magnetic field having various incidence angles.