A Case Study on Explosive Demolition of Gunsan Steam Power Station in Republic of Korea

군산화력발전소 발파해체 실용화 시험시공 사례

  • Published : 2007.12.31

Abstract

The main structure of Gunsan steam power station was demolished by the toppling method using high explosives. Height of a main building is 58m and a total floor area is $292,000m^2$. It is Rahmen(rigid-frame) structure consisted of almost columns and beams and slabs exist only in one part of the building for the electricity generators equipments. To improve the efficiency of blasting work, it is separated into 4 sectors. Blasting floors were 1, 2, 3, & 4 stories from first sector to third sector, while 1, 2, 5, & 7 of fourth sector were blasted because it had not slabs. About 102.675 kg of the MegaMITE were used with 225 electric detonator and 638 non-electric detonators to check detonator connection and confidence of detonation. The blasting noise and vibration were monitored to evaluate the environment effect and the damage of the nearby structures.

군산 화력박선소를 제거하고 새로운 복합화력발전소를 건축하기 위하여 화약을 이용한 상부붕락공법으로 군산 화력발전소의 발파해체를 시행하였다. 군산 화력발전소는 건물 높이 58m, 기력건물의 총면적은 $292,000m^2$이며, 대부분 기둥과 보로 이루어진 라아멘 구조이고 발전설비를 위해 슬래브는 건물의 일부분에만 존재하고 있다. 대상 구조물을 크게 4개 구역으로 분리하였으며 작업의 효율성을 위하여 $1{\sim}3$구역까지는 1층, 2층, 3층, 4층을 발파하였고, 4구역은 슬라브가 없어 1층, 2층, 5층, 7층에 발파를 실시하였다. 적용된 화약은 메가마이트로 102.675kg을 사용하였다. 기폭신뢰도와 결선 여부 확인을 위하여 공내 뇌관으로 비전기뇌관을 638개 적용하였고, 연결뇌관용으로 전기뇌관 225개를 사용하였다. 발파 시 발생하는 환경영향을 평가하기 위하여 소음, 진동을 측정하였으며 이를 통해 인접 구조물의 안전성을 평가하였다.

Keywords

References

  1. Williams, G.T., 1990, Explosive demolition of tall building in inner city areas, Mun. Engr., Vol. 7, No.4, pp. 41-54
  2. Lauritzen, E.K. and M. Peters, 1991, Partial Demolition by Mini - Blasting, Concrete International, Vol. 13, No.6, pp. 43-46