Abstract
Wastewater discharged by industrial activities of metal finishing and electroplating units is often contaminated by a variety of toxic or otherwise harmful substances which have a negative effects on the water environment. The treatment method of heavy metal-cyanide complexes wastewater by alkaline chlorination have already well-known($1^{st}$ Oxidation: pH 10, reaction time 30 min, ORP 350 mV, $2^{nd}$ Oxidation: ORP 650 mV). In this case, the efficiency for the removal of ferro/ferri cyanide by this general alkaline chlorination is very high as 99%. But the permissible limit of Korean waste-water discharge couldn't be satisfied. The initial concentration of cyanide was 374 mg/L(the Korean permissible limit of cyanide is 1.0 mg/L max.). So a particular focus was given to the treatment of heavy metal-cyanide complexes wastewater by $Zn^{+2}/Fe^{+2}$ ion and coprecipitation after alkaline chlorination. And we could meet the Korean permissible limit of cyanide(the final concentration of cyanide: 0.30 mg/L) by $Zn^{+2}/Fe^{+2}$ ion and coprecipitation(reaction time: 30 min, pH: 8.0, rpm: 240). The removal of Chromium ion by reduction(pH: 2.0 max, ORP: 250 mV) and the precipitation of metal hydroxide(pH: 9.5) is treated as 99% of removal efficiency. The removal of Copper and Nickel ion has been treated by $Na_2S$ coagulation-flocculation as 99% min of the efficiency(pH: $9.09\sim10.0$, dosage of $Na_2S:0.5\sim3.0$ mol). It is important to note that the removal of ferro/ferri cyanide of heavy metal-cyanide complexes wastewater should be employed by $Zn^{+2}/Fe^{+2}$ ion and coprecipitation as well as the alkaline chlorination for the Korean permissible limit of waste-water discharge.
중금속 폐수는 다양한 유독성 화합물과 함께 배출되므로 상수원, 토양, 지하수 등의 환경에 악영향을 야기 시킬 수 있다. 이러한 고농도의 복합중금속과 시안착염을 포함한 도금폐수 처리 시 일반적으로 잘 알려진 알카리염소법에 의한($1^{st}$ Oxidation: pH 10, reaction time 30 min, ORP 350 mV, $2^{nd}$ Oxidation: ORP 650 mV) 시안의 잔류농도에 대한 제거효율은 유입수의 시안농도 374 mg/L에 비해 처리 후 잔류시안농도는 3.74 mg/L로써 그 제거효율이 99%로써 상당히 높았으나 수질환경보전법상 수질배출허용기준(나 지역) 1 mg/L 이하에 만족하기 위해서는 2차, 3차 등의 고도처리가 요구됨을 알 수 있었고, 이에 아연백법 및 공침처리공정(reaction time: 30 min, pH: 8.0, rpm: 240)을 적용하여 용해되어 잔류하는 시안착염을 불용성염으로 침전시켜 처리한 결과 잔류시안농도가 1.0 mg/L 이하의 만족할 만한 결과를 있었다. 크롬의 처리는 6가 크롬을 3가 크롬으로 환원(pH: 2.0 max, ORP: 250 mV)시킨 후, 수산화물로 처리(pH: 9.5)시 무난히 99%의 최대 제거효율을 얻을 수 있었다. 폐수 중 나머지 동(Cu)과 니켈(Ni)처리는 황화물 응집침전법을 적용한 결과 최적 pH는 $9.0\sim10.0$에서 $Na_2S$의 최적주입량이 Cu의 경우 0.5 mol에서 99.1%, Ni의 경우 3.0 mol에서 99.0% 이상 제거할 수 있었다. 즉 중금속 복합폐수 중 시안착염은 알카리 염소산화처리법만으로는 수질환경보전법의 규제치 이하로 처리가 불가능 하였고 아연백법 및 공침공정을 같이 적용한 결과 규제치 이하로 처리가 가능하다는 것을 현장 확인할 수 있었다.