Abstract
This paper introduce to improve the reliability of the expected service life and the insulation condition evaluation of the high voltage induction motors by assessing, comparing and analyzing the correlation between the dielectric properties of the off-line insulation diagnostic test and dielectric strength on the insulation breakdown test. The insulation diagnostic tests include insulation resistance, polarization index(P.I.), dissipation factor($tan{\delta}$), maximum partial discharges($Q_{max}$) and AC breakdown test. This study evaluated the correlation between insulation diagnostic test and AC breakdown test for stator winding of high voltage induction motor. On the basis of these test results, we expect that this study can be used for effectively assessing the results of insulation diagnostic tests for similar class induction motors in service at industrial field.
본 논문은 유도전동기 고정자권선의 절연물에 대하여 비파괴 및 파괴시험을 실시하여 절연물의 비파괴특성과 내전압강도와의 상호관계를 비교, 평가, 분석함으로써, 향후 전동기의 절연상태 평가시 수명 및 절연진단의 신뢰성을 도모하고자 제안하였다. 본 논문에서는 비파괴시험과 파괴시험과의 상관관계를 평가하기위하여 비파괴시험으로 절연저항시험, 성극지수시험, 유전정접시험, 부분방전시험을 실시하였으며, 파괴시험은 60[kV] AC 내전압를 이용하여 실시하였다. 또한 장기간 사용된 전동기 권선의 절연물에 대한 연구결과로부터 기존 선진국의 진단방법 및 판정기준이 국내에서 제작된 전동기에 대한 절연특성 평가 및 분석에도 타당함을 증명하였으며, 향후 본 논문에서 제시한 자료들은 유사조건의 산업현장에서 운용중인 유도전동기의 수명 및 상태 평가를 위한 기초자료로 유용하게 사용될 수 있으리라 기대된다.