A Study on SAR Attenuation by Using Loop-type Ground for Mobile Handsets

루프 형태의 접지판을 이용한 휴대폰의 SAR 감쇄에 관한 연구

  • Lee Won-Kew (Department of Electronics Engineering, University of Incheon) ;
  • Son Ji-Myoung (Department of Electronics Engineering, University of Incheon) ;
  • Han Jun-Hee (Department of Electronics Engineering, University of Incheon) ;
  • Yang Woon-Geun (Department of Electronics Engineering, University of Incheon)
  • 이원규 (인천대학교 전자공학과) ;
  • 손지명 (인천대학교 전자공학과) ;
  • 한준희 (인천대학교 전자공학과) ;
  • 양운근 (인천대학교 전자공학과)
  • Published : 2006.09.01

Abstract

In this paper, we investigated SAR(Specific Absorption Rate) value variation by the position and size of the loop-type ground located in a test mobile handset. We carried out simulations on SAR value with loop-type grounds in rear case of a mobile handset, and obtained results showed that different positions and sizes of loop-type grounds had different SAR values. Among investigated positions and sizes of loop-type grounds, the small size case-C showed the best performance; i.e., it showed a decrease efficiency of 8.70 %. And in this case, it showed the highest induced electric-field distribution in the loop-type ground. In the simulation, the folding angle was set to $160^{\circ}$.

본 논문에서는 시험용 휴대폰의 내부에 위치한 루프 형태 접지판의 위치와 크기 변화에 따른 SAR(Specific Absorption Rate) 값의 변화를 검토하였다. 휴대폰의 rear case 안에 있는 루프 형태 접지판에 따른 SAR 값에 대한 전산 모의 실험을 수행하였으며 그 결과 루프 형태 접지판의 위치와 크기에 따라 SAR 값이 달라짐을 보였다. 검토된 루프 형태 접지판의 위치와 크기들 중 small size case-C의 경우가 8.70 %의 감소 효율을 보여 가장 좋은 성능을 보였다. 그리고 이 경우에 루프 형태 접지판에 가장 높은 유도 전계 분포를 보였다. 전산 모의 실험시 폴딩 각도는 $160^{\circ}$로 하였다.

Keywords

References

  1. N. Kuster, Q. Balzano, 'Energy absorption mechanism by biological bodies in the near field of dipole antennas above 300 MHz', IEEE Transactions on Vehicular Technology, vol. 41, no. 1, pp. 17-23, Feb. 1992 https://doi.org/10.1109/25.120141
  2. 윤지훈, 손태호, '휴대폰 전자파의 혈액 조사를 위한 SAR별 TEM 셀의 입력 전력 산출', 한국전자파학회논문지, 16(8), pp. 810-814, 2005년 8월
  3. 전자파 인체 보호기준(안), 정보통신부, 2002년 12월
  4. Z. Wang, X. Chen, 'A low SAR whip type mobile handset antenna', IEE 11th International Conference on Antennas and Propagation, vol. 1, pp. 352-355, Apr. 2001
  5. M. A. Mangoud, R. A. Abd-Alhanmeed, N. J. Mc-Ewan, P. S. Excell, and E. A. Abdulmula, 'SAR reduction for handset with two-element phased array antenna computed using hybrid MoM/FDTD technique', Electronics Letters, vol. 35, no. 20, pp. 1693-1694, Sep. 1999 https://doi.org/10.1049/el:19991166
  6. H. T. Chou, D. J. Wu, 'Radiation of a handset monopole antenna in the presence of a finite shielding sheet for the purpose of SAR reduction', IEEE International Symposium on Antenna and Propagation, vol. 1, pp. 452-455, Jun. 2002
  7. 이윤경, 백락준, 홍진옥, 육재림, 윤현보, '휴대폰 전자파에 노출된 頭部내 SAR 저감을 위한 전자파 흡수체 적용 방법 연구', 한국전자파학회논문지, 14(8), pp. 884-890, 2003년 8월
  8. 홍수원, 오학태, 박천석, 'SAR 저감을 위한 휴대폰 설계', 한국전자파학회논문지, 12(3), pp. 352-359, 2001년 4월
  9. 이규호, 김창일, 양운근, '휴대폰의 폴딩 각도와 휴대폰 케이스의 EMI 방지 도료 분포패턴에 따른 SAR 변화에 관한 연구', 한국전자파학회논문지, 14(4), pp. 421-430, 2003년 4월
  10. 김정호, 김윤명, 'Probe 고정형 SAR 측정 시스템의 구현', 한국전자파학회논문지, 17(2), pp. 221-227, 2006년 2월
  11. Won Kew Lee, Ji Myoung Son, and Woon Geun Yang, 'SAR variation by EMI paint distribution on front case of mobile handsets', Proc. of ICEIC, pp. 339-342, Aug. 2004
  12. 양운근, 이원규, 손지명, 'EMI 도료 패턴과 폴딩 각도에 따른 휴대폰의 SAR 변화에 관한 연구', 한국전자파학회논문지, 16(9), pp. 903-908, 2005년 9월