SMART 연구로 주냉각재펌프의 검증시험

Qualification Test of a Main Coolant Pump for SMART Pilot

  • 박상진 (한국기계연구원 에너지기계연구센터) ;
  • 윤의수 (한국기계연구원 에너지기계연구센터) ;
  • 오형우 (충주대학교 기계공학과)
  • 발행 : 2006.09.01

초록

SMART Pilot is a multipurpose small capacity integral type reactor. Main coolant pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of $310^{\circ}C$ and 14.7MPa. Thus MCP has to be tested under same operating condition as reactor design condition to verify its performance and safety. In present wort a test apparatus to simulate real operating situations of the reactor has been designed and constructed to test MCP. And then functional tests, performance tests, and endurance tests have been carried out upon a prototype MCP. Canned motor characteristics, homologous head/torque curves, coast-down curves, NPSH curves and lift-time performance variations were obtained from the qualification test as well as hydraulic performance characteristics of MCP.

키워드

참고문헌

  1. http://www.smart.re.kr
  2. ASME, 1990, Centrifugal Pumps - Performance Test Codes, ASME PTC 8.2
  3. Wildi, T., 2002, Electrical Machines, Drives, and Power Systems - 5th Ed., Prentice Hall, New Jersey, Chap. 13
  4. Holman, J.P., 1989, Experimental Methods for Engineers - 5th Ed., McGraw-Hill, New York, Chap. 3
  5. Swanson, W.M., 1953, 'Complete Characteristic Circle Diagrams for Turbomachinery,' Trans. of ASME, Vol. 73, pp. 819-826
  6. Kittredge, C.P., 1956, 'Hydraulic Transients in Centrifugal Pump System,' Trans. of ASME, Vol. 76, pp. 1307-1322
  7. Knapp, R.T., 1959, 'Complete Characteristics of Centrifugal Pumps and Their Use in the Prediction of Transient Behavior,' Trans. of ASME, Vol. 79, pp. 683-689
  8. Stepanoff, A.J., 1957, Centrifugal and Axial Flow Pump - 2nd Ed., John Wiley & Sons, New York, Chap.8
  9. Shepherd, D.G., 1957, Principles of Turbomachinery, The Macmillan Company, New York, Chap. 10
  10. Coon, M.T., Leavitt, J.W., Baumgarten, S., Knierim, C. and Moon, S.H., 2005, 'Hydraulic Design of the Reactor Coolant Pumps for APR 1400,' Proceeding of 2005 International Congress on Advances in Nuclear Power Plant
  11. Grist, E., 1999, Cavitation and the Centrifugal Pump; a Guide for Pump Users, Tayler and Francis
  12. Avellan, F., 1993, 'Cavitation Tests of Hydraulic Machines; Procedure and Instrumentation,' Proceedings of ASME Winter Annual Meeting, pp. 91-102
  13. Gillette, J.L., Singer, R.M., Tokar, J.V. and Sullivan, J.E., 1980, 'Experimental Study of the Transition from Forced to Natural Circulation in EBR-II at Low Power and Flow,' J. of Heat Transfer, Vol. 102, No. 3, pp. 525-530 https://doi.org/10.1115/1.3244335