DOI QR코드

DOI QR Code

Detection of Onset and Offset Time of Muscle Activity in Surface EMG using the Kalman Smoother

  • Lee Jung-Hoon (Department of Biomedical Engineering, Graduate School of Yonsei University) ;
  • Lee Hyun-Sook (Department of Oriental Biomedical Engineering, Sangji University) ;
  • Lee Young-Hee (Department of Rehabilitation Medicine, Yonsei University Wonju College of Medicine) ;
  • Yoon Young-Ro (Department of Biomedical Engineering, Graduate School of Yonsei University)
  • Published : 2006.06.01

Abstract

A visual decision by clinical experts like physical therapists is a best way to detect onset and offset time of muscle activation. The current computer-based algorithms are being researched toward similar results of clinical experts. The new algorithm in this paper has an ability to extract a trend from noisy input data. Kalman smoother is used to recognize the trend to be revealed from disorderly signals. Histogram of smoothed signals by Kalman smoother has a clear boundary to separate muscle contractions from relaxations. To verify that the Kalman smoother algorithm is reliable way to detect onset and offset time of muscle contractions, the algorithm of Robert P. Di Fabio (published in 1987) is compared with Kalman smoother. For 31 templates of subjects, an average and a standard deviation are compared. The average of errors between Di Fabio's algorithm and experts is 109 milliseconds in onset detection and 142 milliseconds in offset detection. But the average between Kalman smoother and experts is 90 and 137 milliseconds in each case. Moreover, the standard deviations of errors are 133 (onset) and 210 (offset) milliseconds in Di Fabio's one, but 48 (onset) and 55 (offset) milliseconds in Kalman smoother. As a result, the Kalman smoother is much closer to determinations of clinical experts and more reliable than Di Fabio's one.

Keywords

References

  1. Carlo J. De Luca, 'The use of surface electromyography in biomechanics,' Journal of Applied Biomechanics, vol. 13, pp. 135-163, 1997 https://doi.org/10.1123/jab.13.2.135
  2. S. Micera, G. Vannozzi, A.M. Sabatini, and P. Dario, 'Improving detection of muscle activation intervals,' IEEE Engineering in Medicine and Biology Magazine, 2001
  3. Richard P. Di Fabio, 'Reliability of computerized surface electromyography for determining the onset of muscle activity,' Physical Therapy, vol. 67, pp. 43-48, 1987 https://doi.org/10.1093/ptj/67.1.43
  4. Jacquelin Perry, Gait Analysis: Nonnal and Pathological Function, Delmar Learning, 1992
  5. G.W. Lange, R.A. Hint:errreister, T. Schlegel, et al., 'Electromyographic and kinematic analysis of graded treadmill walking and the implications for knee rehabilitation,' The Journal of Orthopaedic and Sports Physical Therapy, vol. 23, pp. 294-301,1996 https://doi.org/10.2519/jospt.1996.23.5.294
  6. E.J. Cowling, J.R. Steele, 'The effect of upper-limb motion on lower-limb muscle synchrony: Implications for anterior cruciate ligament injury,' Journal of Bone and Joint Surgery: American volume, vol. 83, pp. A:35-41, 2001 https://doi.org/10.2106/00004623-200101000-00005
  7. R.T. Lauer, C.A. Laughton, M. Orlin and B.T. Smith, 'Wavelet decomposition for the identification of EMG activity in the gait cycle,' IEEE, pp. 142-143, 2003
  8. Y.H. Lee, S.I Jeon, C.I Park, ''Properties of the human skeletal muscles revealed by frequency analysis of muscular action potentials during voluntary contraction,' Korean Academy of Rehabilitation Medicine, vol. 18, pp. 311-327, 1994
  9. G.T. Allison, 'Trunk muscle onset detection technique for EMG signals with ECG artefact' Journal of Electromyography and Kinesiology, vol. 13, pp. 209-216, 2003 https://doi.org/10.1016/S1050-6411(03)00019-1
  10. Andrea Merlo, Dirio Farina, and Roberto Merletti, 'A fast and reliable technique for muscle activity detection from surface EMG signals,' IEEE Transactions on Biomedical Engineering, vol. 50, pp. 316-323, 2003 https://doi.org/10.1109/TBME.2003.808829
  11. Greg Welch and Gary Bishop, An Introduction to the Kalman Filter, North Carolina: USA, Chapel Hill, 2004
  12. R.E. Kalman, 'A New Approach to Linear Filtering and Prediction Problems,' Trans. ASME-J. Basic Engr., pp. 35-45, 1960
  13. Mohinder S. Grewal and Angus P. Andrews, Kalman Filtering Theory and Practice, PRENTICE HALL, 1993
  14. Robert Grover Brown and Patrick Y.C. Hwang, Introduction to Random Signal and Applied Kalman Filtering, Wiley, 1997
  15. Y.J. Chung, S.H. Cho, J.H. Lee and S.H. Lee, 'Reliability of the onset time determinations during maximal isometric contraction in surface EMG,' Korean Academy of University Trained Physical Therapists, vol. 1, pp. 51-62, 2003