Abstract
The composite two plate-girder bridges are generally defined as a non-redundant load path structure because the bridge can collapse if one of the two girders is seriously damaged by a fatigue crack. In this paper, a numerical study on the evaluation of the after-fracture redundancy of the composite two-girder bridges was accomplished. The evaluation has been performed on the simple and three-span continuous bridges with I-section cross beams which serve as transverse bracing, and with or without the bottom lateral bracing system. The load carrying capacities of the intact and damaged bridges with or without lateral bracing were evaluated from material and geometric nonlinear analysis, respectively and the redundancy was evaluated for each case. It was acknowledged from the analytical results that both simple and continuous intact two-girder bridges have sufficient redundancy even without lateral bracing, but it takes an important role to improve the redundancy of damaged bridges.
강합성 플레이트 2-거더교는 피로균열에 의해 한 개의 거더에 심각한 손상이 발생되는 경우 교량의 붕괴가 유발되는 단재 하경로 구조로 인식되고 있다. 본 논문에서는 강합성 2-거더교의 거더 손상시 교량의 여유도를 평가하기 위한 해석적 연구를 수행하였다. 여유도 평가는 단경간 및 3경간 연속교를 대상으로 하였으며, 수직브레이싱은 I-단면 가로보로 적용하고 하부 수평브레이싱이 설치되는 경우와 설치되지 않는 경우를 고려하였다. 정상 상태 및 손상 상태의 교량에 대해 하부 수평브레이싱의 유 무에 따른 내하 성능을 재료 및 기하비선형 해석으로 구하고 각 경우의 여유도를 비교 평가하였다. 해석 결과에 따르면 정상 상태의 2-거더 교량은 단순교와 연속교 모두 수평브레이싱이 없어도 여유도가 충분하며, 손상 상태의 교량에서는 수평브레이싱이 여유도 향상에 중요한 역할을 하는 것으로 분석되었다.