Procera System의 역사적 고찰

Procera System : a Review of Literature

  • 신수연 (단국대학교 치과대학 치과보철학교실)
  • Shin, Soo-yeon (Department of Prosthodontics, School of Dentistry, Dankook University)
  • 발행 : 2006.12.30

초록

Procera system으로 제작한 금관은 여러 연구들을 통해 강도, 적합도, 심미성, 시멘트 결합강도, 생체적합성 등에서 우수한 것으로 나타났고 오랜 기간 임상 연구를 통해서도 확인되었다. 따라서 주의 깊고 신중하게 임상에 적용시 만족스러운 보철물 제작이 가능할 것이다.

The availability of high-technology systems that use computer-aided design(CAD) and computer-aided machining(CAM) is on the increase. One such system is the Procera system, which fabricates an all-ceramic crown composed of a densely sintered, high-purity aluminum oxide coping combined with a compatible veneering porcelain. Strength, precision of fit, esthetics, cementation, and biocompatibility are among the many factors that concern clinicians when fabricating all-ceramic restorations with this system. This paper reviews the long history and background development of technical, laboratory and clinical applications and presents, in summary form, the data from the many studies on the Procera system.

키워드

참고문헌

  1. Andersson M, Oden A. A new all-ceramic crown:a dense-sintered, high-purity alumina coping with porcelain. Acta Odontol Scand 1993;51:59-64 https://doi.org/10.3109/00016359309041149
  2. Andersson M, Razzoog ME, Oden A et al. Procera:a new way to achieve an all-ceramic crown. Quintessence Int 1998;29(5):285-296
  3. Prestipino V, Ingber A, Kravitz J. Clinical and laboratory considerations in the use of a new all-ceramic restorative system. Pract Periodont Aesthet Dent 1998;10(5):567-575
  4. Brunton PA, Smith P, McCord JF, Wilson HF. Procera all-ceramic crowns:a new approach to an old problem? Brit Dent J 1999;186(9):430-434 https://doi.org/10.1038/sj.bdj.4800134a
  5. Giordano R. A comparison of all-ceramic restoratie systems:part 2. General Dent 2000;Jan-Feb:38-45
  6. Ottl P, Piwowarczyk A, Lauer HC, Hegenbarth EA. The Procera allceram system. Int J Perio & Resto Dent 2000;20(2): 151-161
  7. Haag P, Andersson M, von Steyern PV, Oden A. 15 years of clinical experience with Procera alumina:a review. Applied Osseointegration Res 2004;4:7-12
  8. Zeng K, Oden A, Rowcliffe D. Flexure tests on dental ceramics. Int J Prosthodont 1996;9(5):434-439
  9. Wagner WC, Chu TM. Biaxial flexural strength and indentation fracture toughness of three new dental core ceramics. J Prosthet Dent 1996;76(2): 140-144 https://doi.org/10.1016/S0022-3913(96)90297-8
  10. Abed HM, Razzoog ME, Lang BR, Yaman P. The effect of alumina core thickness on the fracture resistance of All-ceramic crowns [abstract 394]. J Dent Res 1997;76:63
  11. Potiket N, Chiche G, Finger IM. In vitro fracture strength of teeth restored with different all-ceramic crown systems. J Prosthet Dent 2004;92(5):491-5 https://doi.org/10.1016/j.prosdent.2004.09.001
  12. White SN, Caputo AA, Li ZC, Zhao XY. Modulus of rupture of the Procera all-ceramic system. J Esthet Dent 1996;8(3): 120-126 https://doi.org/10.1111/j.1708-8240.1996.tb01005.x
  13. Zeng K, Oden A, Rowcliffe D. Evaluation of mechanical properties of dental ceramic core materials in combination with porcelains. Int J Prosthodont 1998; 11 (2): 183-189
  14. Harrington Z, McDonald A, Knowles J. An in vitro study to investigate the load at fracture of Procera allceram crowns with various thickness of occlusal veneer porcelain. Int J Prosthodont 2003;16(1):54-58
  15. Webber B, McDonald A, Knowles J. An in vitro study of the compressive load at fracture of Procera allceram crowns with varying thickness of veneer porcelain. J Prosthet Dent 2003;89(2):154-60 https://doi.org/10.1067/mpr.2003.85
  16. Chai J, Takahashi Y, Sulaiman F et ala. Probability of fracture of all-ceramic crowns. Int J Prosthodont 2000; 13(5):420-424
  17. Pallis K, Griggs JA, Woody, RD et al. Fracture resistance of three all-ceramic restorative systems for posterior applications. J Prosthet Dent 2004;91(6): 561-9 https://doi.org/10.1016/j.prosdent.2004.03.001
  18. McLean JM, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971;131:107-111 https://doi.org/10.1038/sj.bdj.4802708
  19. Sulaiman F, Chai J, Jameson LM, Wozniak WT. A comparison of the marginal fit of In-Ceram, IPS Empress and Procera crowns. Int J Prosthodont 1997;10(5):478-484
  20. May KB, Russell MM, Razzoog ME, Lang BR. Precision of fit :the Procera allceram crown. J Prosthet Dent 1998;80(4):394-404 https://doi.org/10.1016/S0022-3913(98)70002-2
  21. Dahlmo K, Andersson M, Gellerstedt M, Karlsson S. On a new method to assess the accuracy of a CAD program. Int J Prosthodont 2001;14(3):276-83
  22. Kokubo Y, Ohkubo C, Tsumita M et al. Clinical marginal and internal gaps of Procera allceram crowns. J Oral Rehabil 2005;32:526-530 https://doi.org/10.1111/j.1365-2842.2005.01458.x
  23. Hegenbarth EA. Procera aluminum oxide ceramics:a new way to achieve stability, precision and esthetics in all-ceramic restorations. Quintessnece Dent Tech 1995:21-34
  24. Heffernan MJ, Aquilino SA, Diaz-Arnold AM, et al. Relative translucency of six all-ceramic systems. Part I:core materials. J Prosthet Dent 2002;88(1):4-9 https://doi.org/10.1067/mpr.2002.126794
  25. Heffernan MJ, Aquilino SA, Diaz-Arnold AM, et al. Relative translucency of six all-ceramic systems. Part II:core materials. J Prosthet Dent 2002;88(1): 10-15 https://doi.org/10.1067/mpr.2002.126795
  26. Abed HM, Razzoog ME, Lang BR, Yaman P. Masking ability of Procera allceram copings using different substructure material [abstract 281]. J Dent Res 2000;79: 179
  27. Fradeani M, D'Amelio M, Redemagni M, Corrado M. Five-year follow-up with Procera all-ceramic crowns. Quintessence Int 2005;36(2): 105-113
  28. Blixt M, Adamczak E, Linden LA et al. Bonding to densely sintered alumina surfaces : Effect of sandblasting and silica coating on shear bond strength of luting cements. Int J Prosthodont. 2000;13(3) :221-6
  29. Blatz MB, Sadan A, Martin J, Lang B. In vitro evaluation of shear bond strengths of resin to densely-sintered high-purity zirconium-oxide ceramic after long-term storage and thermal cycling. J Prosthet Dent 2004;91:356-62 https://doi.org/10.1016/j.prosdent.2004.02.001
  30. Blatz MB, Sadan A. In vitro evaluation of long-term bonding of Procera allceram alumina restorations with a modified resin luting agent. J Prosthet Dent 2003;89(4):381-387 https://doi.org/10.1067/mpr.2003.89
  31. Blatz MB, Sadan A, Kern M. Resin-ceramic bonding:a review of literature. J Prosthet Dent 2003;89(3):268-274 https://doi.org/10.1067/mpr.2003.50
  32. Messer RL, Lockwood PE, Wataha JC et al. In vitro cytotoxicity of traditional versus contemporary dental ceramics. J Prosthet Dent 2003;90(5):452-458 https://doi.org/10.1016/S0022-3913(03)00533-X
  33. Wilson PD, Hacker CH, Razzoog ME et al. An investigation of enamel wear opposing allceram coping [abstract 3] J Dent Res 1997;76:63
  34. Rekow ED . CAD/CAM in dentistry:a historical perspective and view of the future. J Can Dent Assoc 1992;58(4):283-288
  35. Preston JD , F Duret. CAD/CAM in dentistry. Oral Health 1997;March:17-27
  36. Altschuler MD, Altschuler BR, Toboada J. Laser electro-optical system for rapid 3-D topographic mapping of surfaces. Optical Engineering 1981;20(6): 953-961
  37. Duret F. Prosthese assitee par ordinateur demonstration en TV direct. 1986;5:10-16
  38. Rekow ED. Computer-aided design and manufacturing in dentistry:a review of the state of the art. J Prosthet Dent 1987;58(4)512-516 https://doi.org/10.1016/0022-3913(87)90285-X
  39. Qualtrough AJE, Piddock V. Dental CAD/CAM:a millstone or a milestone? Dental Technology 1995;June:200-204
  40. Hickel R, Dasch W, Mehl A, Kremers L. CAD/CAM-filling of the future? Int Dental J 1997;47(5):247-258 https://doi.org/10.1002/j.1875-595X.1997.tb00785.x
  41. McLaren EA, Terry DA. CAD/CAM systems, materials and clinical guidelines for all-ceramic crowns and fixed partial dentures. Compendium 2002;23(7):637-654
  42. Witkowski S. (CAD-)/CAM in dental technology. Quintessence Dent Technol 2005;2: 169-184
  43. Andersson M, Bergman B, Bessing C et al. Clinical results with titanium crowns fabricated with machine duplication and spark erosion. Acta Odontol Scand 1989;47:279-286 https://doi.org/10.3109/00016358909007713
  44. Russel MM, Andersson M, Dahlmo K et al. A new computer-assisted method for fabrication of crowns and fixed partial dentures. Quintessence Int 1995;26(11):757-763
  45. Oden A, Andersson M, Krystek-Ondracek I, Magnusson D. Five-year clinical evaluation of Procera allceram crowns. J Prosthet Dent 1998;80(4):450-456 https://doi.org/10.1016/S0022-3913(98)70010-1
  46. Odman P, Andersson B. Procera allceram crowns followed for 5 to 10.5 years:a prospective clinical study. Int J Prosthodont 2001;14(6):504-509
  47. Fradeani M, D'Amelio M, Redemagni M, Corrado M. Five-year follow-up with Procera all-ceramic crowns. Quintessence Int 2005;36(2): 105-113
  48. Hagenbarth EA. Esthetic and prosthetic considerations of Procera development on implants and teeth-a technical analysis. Applied Osseointegration Res 2004;4:22-26