An Experimental Study on the Behavior of the Perforated Rib Connector with Shearing Bars

전단구속철근을 배치한 유공강판 전단연결재에 관한 실험적 연구

  • Received : 2006.09.28
  • Published : 2006.11.30

Abstract

In the design of composite structures, shear connectors such as headed stud, channel, perforated plate, etc, are commonly used to transfer longitudinal shear forces across the steel-concrete interface. Many researches have been conducted to improve the characteristics of different types of shear connector. This paper presents the results of 11 push-out tests performed on the new perforated rib connectors with shearing bars embedded in concrete slab under static loads. The results obtained from these tests are as following : 1) The bearing plate welded on both sides of perforated rib plate improves the stiffness and strength. 2) The capacity of perforated connectors is influenced primarily by the transverse reinforcements and shearing bars.

강 콘크리트 합성구조에서 강재와 콘크리트 사이의 경계면에 효과적인 응력전달과 합성거동을 유도하기 위하여 스터드, 채널, 유공강판 등이 사용된다. 가장 광범위하게 사용하는 전단연결재는 스터드 형식이고, 최근에 들어서는 강판에 구멍을 뚫은 유공강판전단연결재인 Perfobond가 주목을 받고 있다. 본 연구는 강 콘크리트 합성교량에 적용하기 위한 Perfobond형 전단연결재의 연성능력과 전단성능을 향상시킬 목적으로 횡방향 전단구속철근을 배치하고, Push-out 실험을 수행하여 전단내력을 비교하였다. 실험결과, 유공강판 전단연결재에 전단구속철근, 횡방향 관통철근, 단부 지압판 등을 설치함에 따른 수평 저항성능이나 다웰효과 등에 의해 전단내력이 상승하였으며, 또한 최대내력 이후 변형능력이 유지되면서 연성거동 특성을 보였다.

Keywords

References

  1. 김영호 외 4, "엇갈려 찟은 유공강판 전단연결재(출원번호10-2003-0068475), 특허청 특허공개정보, 2003.
  2. 정철헌, 이흥수, 박종면, 김영호, "합성작용을 위한 새로운 Perfobond 전단연결재", 대한토목학회 논문집, 제24권 제4A호, pp.807-816, 2004.
  3. Wilhelm Zellner, "Recent Designs of Composite Bridges and a New Type of Shear Connectors", Composite Construction in Steel and Concrete, American Society of Civil Engineers, New York, NY., 1987.
  4. Oguejiofor, E.C. and Hosain, M.U., "Behaviour of Perfobond Rib Shear Connectors in Composite Beam : Full Size Tests", Canadian Journal of Civil Engineering, 19(2), pp.224-235, 1992. https://doi.org/10.1139/l92-028
  5. Oguejiofor, E. C. and Hosain, M. U. "A Parametric Study of Perfobond Rib Shear Connector", Canadian Journal of Civil Engineerign, Vol. 21, pp. 614-625, 1994. https://doi.org/10.1139/l94-063
  6. Medberry, S. B. and Shahrooz B. M., "Perfobond Shear Connector for Composite Construction," Engineering Journal, American Institute of Steel Construction, First Quarter, pp. 2-12, 2002.
  7. Eurocode 4. ENV(1994), "Design of Composite Steel and Concrete Structures", European Committee for Standardisation(CEN), 1997.
  8. J.W. Fisher and R.G. Slutter, "Fatigue Strength of Shear Connectors", High Research Record 104, HRB, 1966.
  9. Isabel Valente, Paulo J.S. Cruz, "Experimental analysis of Perfobond shear connection between steel and lightweight concrete", Journal of Constructional Steel Research, Vol.60, pp.465-479, 2004. https://doi.org/10.1016/S0143-974X(03)00124-X
  10. 日本土木學會, 鋼.コンクリート合成構造の設計ガイドライン, 구조공학シリーズ 3, 1989.