Sensitivity Analysis of Amino Acids in Simulated Moving Bed Chromatography

  • Lee, Ju-Weon (Center for Advanced Bioseparation Technology, Inha University) ;
  • Lee, Chong-Ho (Center for Advanced Bioseparation Technology, Inha University) ;
  • Koo, Yoon-Mo (Center for Advanced Bioseparation Technology, Inha University)
  • 발행 : 2006.04.30

초록

We conducted a sensitivity analysis of the simulated moving bed (SMB) chromatography with the case model of the separation of two amino acids phenylalanine and tryptophan. We consider a four-zone SMB chromatography where the triangle theory is used to determine the operating conditions. Competitive Langmuir isotherm model was used to determine the adsorption isotherm. The finite difference method is used to solve nonlinear partial differential equation (PDE) systems numerically. We examined the effects of alterations in the operating conditions(feed-extract, feed-raffinate, eluent-extract, eluent-raffinate, recycle, and switching time) and the adsorption isotherm parameters (Langmuir isotherm parameters a and b) on SMB efficiency. The variation range of operating conditions and Langmuir isotherm a was between -50 and 50% of original value and the variation range of the Langmuir isotherm b was between $2.25^{-5}$ and $2.25^5$ times of original value.

키워드

참고문헌

  1. Jacobson, J. M., J. H. Frenz, and C. Horvath (1987) Measurement of competitive adsorption isotherm by frontal chromatography. Ind. Eng. Chem. Res. 26: 43-50 https://doi.org/10.1021/ie00061a009
  2. Wu, D.-J., Y. Xie, Z. Ma, and N.-H. L. Wang (1998) Design of simulated moving bed chromatography for amino acid separations. Ind. Eng. Chem. Res. 37: 4023-4035 https://doi.org/10.1021/ie9801711
  3. Pais, L. S., J. M. Loureiro, and A. E. Rodrigues (2000) Chiral separation by SMB chromatography. Sep. Purif. Technol. 20: 67-77 https://doi.org/10.1016/S1383-5866(00)00063-0
  4. Yang, Y. J., C. H. Lee, and Y. M. Koo (2004) Separation of amino acids by simulated moving bed using competitive Langmuir isotherm. Biotechnol. Bioprocess Eng. 9: 1-8 https://doi.org/10.1007/BF02949314
  5. Yoon, T. H., B. H. Chung, I. H. Kim (2004) A novel design of simulated moving bed (SMB) chromatography for separation of ketoprofen enantiomer. Biotechnol. Bioprocess Eng. 9: 285-291 https://doi.org/10.1007/BF02942345
  6. Hong, S. P., C. H. Lee, S. K. Kim, H. S. Yun, J. H. Lee (2004) Mobile phase compositions for ceramide III by normal phase high performance liquid chromatography. Biotechnol. Bioprocess Eng. 9: 47-51 https://doi.org/10.1007/BF02949321
  7. Xie, Y., Y. M. Koo, and N.-H. L. Wang (2001) Preparative chromatographic separation: Simulated moving bed and modified chromatography methods. Biotechnol. Bioprocess Eng. 6: 363-375 https://doi.org/10.1007/BF02932317
  8. Mazzotti, M., G. Storti, and M. Morbidelli (1997) Optimal operation of simulated moving bed units for nonlinear chromatographic separations. J. Chromatogr. A 769: 3-24