Microscopic Imaging of Articular Cartilage using Polarization-Sensitive Optical Coherence Tomography

  • Lee Sang-Won (Department of Biomedical Engineering, College of Health Sciences, Yonsei University) ;
  • Oh Jung-Taek (Institute for Medical Engineering, Yonsei University) ;
  • Kim Beop-Min (Department of Biomedical Engineering, College of Health Sciences, Yonsei University)
  • 발행 : 2005.02.01

초록

We construct and test the polarization-sensitive optical coherence tomography (PS-OCT) system for imaging porcine and human articular cartilages. PS-OCT is a new imaging technology that provides information regarding not only the tissue structures but tissue components that show birefringence such as collagen. In this study, we measure the cartilage thickness of the porcine joint and the phase retardation due to collagen birefringence. Also, we demonstrate that changes of the collagen fiber orientation could be detected by the PS-OCT system. Finally, differences between normal and damaged human articular cartilage are observed using the PS-OCT system, which is then compared with the regular histology pictures. As a result, the PS-OCT system is proven to be effective for diagnosis of the pathology related to the cartilage. In the future, this technology may be used for discrimination of the collagen types. When combined with endoscope technologies, the PS-OCT images may become a useful tool for in vivo tissue testing.

키워드

참고문헌

  1. S.H. Lee, Human Anatomy, Hyunmoon, pp. 129-154, 1999
  2. M.J. Robers, S.B. Adams Jr, N.A. Patel, D.L. Stamper, M.S. Westmore, S.D. Martin, J.G. Fujimoto, and M.E. Brezinski, 'A new approach for assessing early osteoarthritis in the rat' , Analytical and Bioanalytical Chemistry, Vol. 377, No.6, pp. 1003-1006, 2003 https://doi.org/10.1007/s00216-003-2225-2
  3. D. Huang, E.A. Swanson, C.P. Lin, J.S. Schuman, W.G. Stinson, W. Chang, M.R. Hee, T. Flotte, K. Gregory, C.A. Puliafito, and J.G. Fujimoto, 'Optical coherence tomography', Science, Vol. 254, pp. 1178-1181, 1991 https://doi.org/10.1126/science.1957169
  4. E.A. Swanson, Optical coherence tomography principles, instrumentation, and biological applications, Biomedical Optical Instrumentation and Laser-Assisted Biotechnology, pp.291-303, 1996
  5. B.E. Bouma, G.J. Tearney, Handbook of Optical coherence tomography, Marcel Dekker, Inc., 2002
  6. J.F. de Boer, S.M. Srinivas, B.H. Park, T.H. Pham, Z. Chen, T.E. Milner, and J.S. Nelson, 'Polarization effects in optical coherence tomography of various biological tissues', IEEE Journal of selected topitcs in quantum electornics, Vol. 5, No.4, pp. 1200-1204, 1999 https://doi.org/10.1109/2944.796347
  7. J.F. de Boer, T.E. Milner, 'Review of polarization sensitive optical coherence tomography and Stokes vector determination', Journal of Biomedical Optics, Vol. 7, No. 3, pp. 359-371, 2002 https://doi.org/10.1117/1.1483879
  8. H. Ren, Z. Ding, Y. Zhao, J. Miao, J.S. Nelson, and Zhongping Chen, 'Phase-resolved junctional optical coherence tomography : simultaneous imaging of in situ tissue structure, blood flow velocity, standard deviation, birefringence, and Stokes vectors in human skin', Optics Letters, Vol. 27, No. 19, pp. 1702-1704, 2002 https://doi.org/10.1364/OL.27.001702
  9. Y. Zhao, Z. Chen, Z. Ding, H. Ren, and J.S. Nelson, 'Realtime phase-resolved functional optical coherence tomogrphy by use of optical Hilbert transformation', Optics Letters, Vol. 27, No.2, pp. 98-100, 2002 https://doi.org/10.1364/OL.27.000098
  10. Eugene Hecht, Optics Fourth edition, Addison Wesley, pp. 325-384, 2002
  11. J.T. Oh, B.M. Kim, and S.W. Kim, 'Statical characteristics of polarization-sensitive optical coherence tomography for tissue imaging', Journal of the Optical Society of Korea, Vol. 7, No.4, pp. 211-215, 2003
  12. C.K. Hitenberger, E. Gotzinger, M. Sticker, M. Pircher, and A.F. Fercher, 'Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography' , Optics Express, Vol. 9, No. 13, pp. 780-790, 2001 https://doi.org/10.1364/OE.9.000780
  13. M.C. Pierce, J. Strasswimmer, B.H. Park, B. Cense, and J.F. de Boer, 'Birefringence measurements in human skin using polarization-sensitive optical coherence tomography', Journal of Biomedical Optics, Vol. 9, No.2, pp. 287-291, 2004 https://doi.org/10.1117/1.1645797
  14. M.R. Hee, D. Huang, E.A. Swanson, and J.G. Fujimoto, 'Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging', Journal of Optical Society of America B, Vol. 9, No.6, pp. 903-908, 1992
  15. C.E. Saxer, J.F. de Boer, B.H. Park, Y. Zhao, Z. Chen, and J.S. Nelson, 'High-speed fiber-based polarization-sensitive optical coherence tomography of in vivo human skin', Optics Letters, Vol. 25, No. 18, pp.1355-1357, 2000 https://doi.org/10.1364/OL.25.001355
  16. J. Zhang, S. Guo, W.G. Jung, J.S. Nelson, and Z. Chen, 'Determination of birefringence and absolute optic axis orientation using polarization-sensitive optical coherence tomography with PM fibers', Optics Express, Vol. 11, No. 24, pp. 3262-2370, 2003
  17. P.H. Tran, D.S. Mukai, M. Brenner, and Z. Chen, 'In vivo endoscopic optical coherence tomography by use of a rotational microelectromechanical system probe', Optics Letters, Vol. 29, No. 11, pp. 1236-1238, 2004 https://doi.org/10.1364/OL.29.001236