The Evaporation Shape of Deposited Droplet on the Hot Surface

고온표면에 부착된 액적의 증발형상 변화

  • Bang Chang-Hoon (Department of Fire Protection Engineering, Kyungpook College)
  • 방창훈 (경북전문대학 소방안전관리과)
  • Published : 2005.03.01

Abstract

The objective of the present work is to examine the evaporation shape of deposited droplet on the hot surface. this paper performed the experiments as following conditions: (a) the surface temperature is within the range between $80^{\circ}C$ and $95^{\circ}C$ in the conduction and radiation, (b) droplet diameter is 3.0mm. The results are as follows; while droplet evaporates, droplet's radius is kept changelessly to $70\%$ evaporation time and droplet's shape is kept changelessly after. In case use Constant radius model, about $10\%$ is appearing high than value that time-averaged heat flux applies Inverse heat conduction.

Keywords

References

  1. Dawson, H., Di Marzo, M., 'An Experimental Study of Multiple Droplet Evaporative Cooling', NIST-GCR 93-624, 1993
  2. Zhang, N., Yang, W. J., 'Natural Convection in Evaporating Minute Drops', J. of Heat Transfer, Vol. 104, pp. 656-662, 1982 https://doi.org/10.1115/1.3245182
  3. Sadhal, S. S., Plesset, M. S., ' Effect of Solid Properties and Contact Angle in Dropwise Condensation and Evaporation', J. of Heat Transfer, Vol. 101, pp. 48-54, 1979 https://doi.org/10.1115/1.3450934
  4. Riu, K. J., Bang, C. H. and Kim, J. S., Evaporation Cooling of Single Droplet on a Heated Solid Surface, KSME(B), Vol. 25, No. 6, pp. 845-852, 2001
  5. Chandra, S., DiMarzo, M., Qiao, Y. M., Tartarini, P., 'Effect of solid-liquid Contact Angle on Droplet Evaporation', NIST-GCR-96-687, 1995