An Experimental Study on Shear Strength of Set Anchors Installed in Plain Concrete

무근콘크리트에 매입된 셋트앵커의 전단내력평가에 관한 실험적 연구

  • Received : 2005.03.02
  • Accepted : 2005.06.10
  • Published : 2005.06.27

Abstract

This paper concerns the prediction of shear capacity, as governed by steel failure and concrete breakout failure, of set anchors installed in plain concrete. For this purpose, the methods to evaluate the shear capacity of the set anchors in concrete are summarized and the experimental data are compared with capacities by the two present methods : the method of ACI349-90 and the Concrete Capacity Design (CCD) method. (1) The constant-0.684 in the steel strength equation of set anchor was determined from shear test data at the 5 percent fractile probability. Consequently, it was concluded that the constant-0.6 and 0.5 in the steel strength equation for steel failure of ACI318-02 and EOTA were safe. The nominal shear strength of set anchor was proposed as following. $V_s=0.684 A_{se}f_{ut}$. (2) The CCD method was considered reasonable in estimating the concrete breakout strength of set anchors. In terms of the CCD method, the nominal concrete breakout strength of set anchor in shear was provided as follows; $V_b=0.609(\frac{\iota}{d_o})^{0.2}\sqrt{d_0}\sqrt{f_c}(c_1)^{1.5}$(N). (3) The CCD method was considered reasonable in estimating the concrete breakout strength for spacing of set anchors. The proposed equation was considered safe in estimating the concrete breakout strength for spacing of set anchors.

익스팬션 앵커인 셋트앵커를 대상으로 실험을 통하여 전단내력에 대해서 고찰하였다. 실험은 연단거리와 앵커간격을 변수로 하여 진행하였으며 전단하중을 받는 앵커의 파괴모드는 연단거리와 앵커의 강성 및 직경에 영향을 받는 것으로 나타났다. 앵커와 모재인 콘크리트의 파괴모드는 앵커의 설계식에 중요한 요소이며, 본 실험에서는 앵커의 전단파괴와 콘크리트 단부파괴가 나타났다. 앵커의 전단강도는 ACI 318-02 설계기준과 EOTA 기준을 비교 검토하여 평가하였으며, 콘크리트 단부파괴강도는 CCD 방법과 기존의 ACI349-90 설계기준을 비교.검토하여 평가하였다. 셋트앵커의 실험결과, (1) 셋트앵커의 전단강도에서 앵커의 계수는 5% 파괴확률을 적용하여 0.684로 평가되었다. 그러므로 ACI318-02와 EOTA의 앵커의 전단강도에 대한 각각의 계수 0.6과 0.5는 안전 측으로 판단된다. 따라서 셋트앵커의 전단강도를 다음과 같이 제시한다. $V_s=0.684 A_{se}f_{ut}$(N). (2) 콘크리트 단부파괴강도 예측값은 CCD방법을 적용한 예측값이 비교적 실험값에 근접했다. 그러므로 CCD방법에 근거하여 5% 파괴확률을 적용한 셋트앵커의 콘크리트 단부파괴강도를 다음과 같이 제시한다. $V_b=0.609(\frac{\iota}{d_o})^{0.2}\sqrt{d_0}\sqrt{f_c}(c_1)^{1.5}$(N). (3) 앵커간격에 따른 콘크리트 단부파괴강도 추정 시 CCD 설계기준이 합리적인 설계방법으로 사료된다.

Keywords

References

  1. 김규석(2003) 비균열무근콘크리트 매입된 앵커의 전단내 력, 대한건축학회 구조계 논문집, 제19권 제9호, 2003. 9
  2. 김규석, 서성연, 김성용 (2003) 비균열 무근콘크리트에 매입된 익스팬션앵커의 인발내력, 대한건축학회 구조 계 논문집, 제19권 제11호, 2003년 11월호
  3. 김규석, 김성용 (2003) 익스팬션앵커의 콘파괴강도 평가, 한국강구조학회 논문집, 제15권 제6호, 2003년 12 월호
  4. W. Fuchs, R. Eligehausen, and J. E. Breen Concrete Capacity Design(CCD) Approach for Fastening to Concrete, ACI Structural Journal. vol. 92,1995
  5. ACI Committee 318, Building Code Requirements for Structural Concrete and Commentary, 2002
  6. EOTA, Annex C Design Methods for Anchorages, 2001
  7. ACI Committee 355, Evaluating the Performance of Post-Installed Mechanical Anchors in Concrete(ACI 355.2-00), American Concrete Institute. 2000
  8. ACI Committee 214-02, Evaluation of Strength Test Results of Concrete, 2002
  9. EOTA Part One Anchors in General, 2001
  10. AISC, Load and Resistance Facto Design Specification for Structural Steel Buildings, 2nd Edition, Chicago, Dec. 1999, 327 pp
  11. ASTM E488-96, Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements, 1996
  12. CEB Task Group VI/5, fastening to Reinforced Concrete and Masonry Structures : Design and Detailing, Volume 1, Euro-International Concrete Committee (CEB), May 1991
  13. C. B. Farrow, Tensile Capacity of Anchors with Partial or Overlapping Failure Surface, M.S. Thesis, The University of Texas at Austin, August, 1992
  14. G. Rehm, R. Eligehausen, and R. Mallee, Befestigungstechik, Beitragzum Betonkalendar, 1988
  15. H. B. Albert, and J, L. Gerald, Engineering Statistics, Prentich Gall, 1972
  16. I. Frigui, Tensile Capacity of Single Anchors in Concrete, M.S. Thesis, The University of Texas at Austin, August, 1992
  17. J. H. Gross, R. E. Klingner, and H. L. Graves, III, Dynamic Behavior of Single and Double Near-Edge Anchors Loaded in Shear, ACI Structural Journal. vol. 98, 2001
  18. J. M. Hallowell, Tensile and Shear Behavior of Anchors in Uncracked and Cracked Concrete under Static and Dynamic Loading, M.S. Thesis, The University of Texas at Austin, August, 1996
  19. PCI, PCI design handbook-Precast and Prestressed Concrete, 3rd Edition, Prestressed Concrete Institute, Chicago, 1985
  20. PCI, PCI design handbook-Precast and Prestressed Concrete, 5rd Edition, Prestressed Concrete Institute, Chicago, 1999
  21. R. A. Cook, Behavior and Design of Ductile Mutiple-Anchor Steel-to-Concrete Connections, Ph.D. Dissertation. The University of Texas at Austin, August, 1989
  22. R. Eligehausen, and W. Fuchs, Loadbearing Behavior of Anchor Fastenings under Shear, Combined Tension and Shear of Flexural Loading, Betonwerk + Fetigteil-Technik, Berlin, No.2, 1988, pp.44-56
  23. R. Eligehausen, W. Fuchs, and B. Mayer, Tragverhalten von Dubelbefestigungen bei Zugbeanspruchung, Betonwerk + Fertigteil -Technik, Berlin, No.1, 1988, pp.29-35
  24. R. W. Sutton, and D. Meinheit, Evaluation of Expansion Anchor Ultimate tensile capacity Prediction Equations, anchors in Concrete : Design and Behavior, SP-130, american Concrete Institute. Detroit, 1991. pp. 19-46
  25. TVA Civil Design Standard No. DS-C.1.7.1, General Anchorage to Concrete, Tennessee Valley Authority, Knoxville, TN, 1984