DOI QR코드

DOI QR Code

A Study on the Operational Characteristic with the Scale Effect of the Cross-Flow Fan

치수효과를 고려한 횡류홴의 작동특성연구

  • 김형섭 (성균관대학교 기계공학부 대학원) ;
  • 김윤제 (성균관대학교 기계공학부)
  • Published : 2005.06.01

Abstract

One of noticeable features in the cross flow fan is that a working fluid passes through impeller blade twice without distinction between the inlet and exit angles. Also, it does produce higher circumferential velocity than other types of blade at the same flow rate in accordance with the application of the forward curved shape. However, a design theory for the cross-flow fall has not yet been formed owing to an eccentric vortex, which is the remarkable characteristics, occurred in a cross-flow fan. Furthermore, the eccentric vortex, which is difficult to control the size and position, is the important cause of performance decrease. In this study, experiments we carried out to estimate the similarity of the cross-flow fan with various scales and rotational velocity changes. Pressure coefficients to flow coefficients with various scales of the cross-flow fan are plotted to the application of the general similarity law of the turbomachinery in the cross-flow fan with Archimedes spiral, which is the important factor having an effect on it.

Keywords

References

  1. Eck, B., 1973, Fans, Pergamon Press, New York
  2. Murada, S. and Nishihara, K., 1976, 'An Experimental Study of Cross Flow Fan (1st Report, Effects of Housing Geometry on the Fan Performance)', JSME, Vol. 19, No. 129, pp. 314-321
  3. Tanaka, S. and Murata, S., 1994, 'Scale Effects in Cross-Flow Fans (2nd Report, Effects of Fan Dimensions on Flow Fields and the Universal Representation of Characteristics)', JSME, Vol. 59, No. 560, pp. 1153-1160
  4. Tanaka, S. and Murata, S., 1995, 'Scale Effects in Cross-Flow Fans', JSME International Journal series B, Vol. 38, No.3, pp. 388-397
  5. Lazzaretto, A., Toffolo, A., and Martegani, A. D., 2001, 'On Cross-Flow Fan Similarity: Effects of Casing Shape', Journal of Fluids Engineering, Vol. 123, pp. 523-531 https://doi.org/10.1115/1.1379033
  6. Lazzaretto, A., 2003, 'A Criterion to Define Cross - Flow Fan Design Parameters', Journal of Fluids Engineering, Vol. 125, pp. 680-683 https://doi.org/10.1115/1.1593709
  7. Lazzaretto, A., Toffolo, A., and Martegani, A. D., 2001, 'A Systematic Experimental Approach to Cross-Flow Fan Design', Journal of Fluids Engineering, Vol. 123, pp. 684-693
  8. 구형모, 최원석, 오병재, 이진교, 1998, '공조기기용 횡단류팬에 대한 실험적 연구: 기본적 설계변수의 영향에 관한 연구', 대한기계학회 춘계학술대회 논문집 B, pp. 438-443
  9. 진심원, 이진하, 서상호, 이내영, 임금식, 1995, '에어콘용 횡류팬의 고풍량화에 대한 실험적 연구', 공기조화냉동공학회, 동계학술발표논문집, pp. 234-241
  10. 진심원, 이내영, 1998, '횡류홴 응용의 실험적 연구', 공기조화냉동공학회, 동계학술발표회논문집, pp. 544-549