CSP [Chiral Stationary phase] for SMB Chromatography

SMB 크로마토그래피에서 키랄정지상 [Chiral Stationary Phase, CSP]의 사용

  • Kim Byung-Lip (Department of Chemical Engineering, Chungnam National University) ;
  • Kim In-Ho (Department of Chemical Engineering, Chungnam National University)
  • Published : 2005.06.01

Abstract

Simulated moving bed (SMB) chromatography was used in the petrochemical industry in the 1960s and its use has been widened to separate chiral compounds in the 1990s. Chiral stationary phase (CSP) is the key component in SMB for the separation of the chiral compounds. CSP has been developed for the analytical use in HPLC, however, its development successfully adapted for the preparative use in SMB chromatography. This review covers the present state-art technology of CSP for SMB chromatography in terms of selectivity, stability, and capacity.

Keywords

References

  1. Subramanian, G. (2001), Chiral Separation Techniques, New York, Wiley-VCH
  2. Francotte, E. (1994), Contribution of preparative chromatographic resolution to the investigation of chiral phenomena, J. Chroma. A. 666, 565-601 https://doi.org/10.1016/0021-9673(94)80419-2
  3. Guiochon, G., S. Golshan Shirazi, and A. Katti (1994), Fundamentals of preparative and nonlinear chromatography, Boston, Academic Press
  4. Ruthven, D. M. and C. B. Ching (1989), Counter-current and simulated counter-current adsorption separation processes, Chem. Eng. Sci. 44, 1011-1038 https://doi.org/10.1016/0009-2509(89)87002-2
  5. Juza, M., M. Mazzotti, and M. Morbidelli (2000), Simulated moving-bed chromatography and its application to chirotechnology, Trends Biotechnol. 18, 108-118 https://doi.org/10.1016/S0167-7799(99)01419-5
  6. Johnson, J. A. and R. G. Kabza (1993), SORBEX: Industrial-scale adsorptive separation, In Preparative and Production Scale Chromatography, G. Ganetos and P. E. Barker Eds., Marcel Dekker, New York
  7. Ganetos, G. and P. E. Barker (1993), Preparative and Production Scale Chromatography Marcel Dekker, New York
  8. http://www.fda.gov/cder/news/thalidomide.htm
  9. http://www.polymer.or.kr/suite/conference
  10. Pirkle, W. H. and B. C. Hamper (1991), The direct preparative resolution of enantiomers by liquid chromatography on chiral stationary phases, In Preparative Liquid Chromatography, B. A. Bildingmeyer Ed., Elsevier Science Publishers, Amsterdam
  11. Negawa, M. and F. Shoji (1992), Optical resolution by simulated moving-bed adsorption technology, J. Chromato. A. 590, 113-117 https://doi.org/10.1016/0021-9673(92)87011-V
  12. Nicoud, R. M. (1993), A packing procedure for high flow rate and high stability columns using cellulose triacetate, LC - GC Int. 6, 636-637
  13. Zhang, Y., D. R. Wu, D. B. Wang-Iverson, and A. A. Tymiak (2005), Enantioselective chromatography in drug discovery, Drug Discovery Today, 10, 571-577 https://doi.org/10.1016/S1359-6446(05)03407-0
  14. http://pubs.acs.org/ceu/coverstory/8224/8224chiral.html
  15. Shulte, M. and J. Strube (2001), Preparative enantioseparation by SMB chromatography, J. Chromato. A, 906, 399-416 https://doi.org/10.1016/S0021-9673(00)00956-0
  16. http://choongin.com/211d_2a.htm
  17. http://www.registech.com
  18. Pirkle, W. H., D. W. House, J. H. Finn (1980), Broad spectrum resolution of optical isomers using chiral high-performance liquid chromatographic bonded phases, J. Chromato., 192, 143-158 https://doi.org/10.1016/S0021-9673(00)81849-X
  19. Job, G. E., A. Shvets, W. H. Pirkle et al. (2004), The effects of aromatic substituents on the chromatographic enantioseparation of diarylmethyl esters with the Whelk-O1 chiral stationary phase, J. Chromato. A. 1055, 41-53 https://doi.org/10.1016/j.chroma.2004.08.001
  20. K. Mihlbachler., A. Jupke, A. Seidel-Morgenstern, H. Schmidt-Traub, and G. Guiochon (2002), Effect of the homogeneity of the column set on the performance of a simulated moving bed unit: II. Experimental study, J. Chromato. A. 944, 3-22 https://doi.org/10.1016/S0021-9673(01)01396-6
  21. Application guide, Daicel Chemical Ltd
  22. Nicoud, R. M. (1999), The separation of optical isomers by SMB chromatography, Pharmaceutical Technology Europe, March, 0330
  23. K. Mihlbachler., K. Kaczmarski, A. Seidel-Morgenstern, and G. Guiochon (2002), Measurement and modeling of the equilibrium behavior of the Troeger hase enantiomers on an amylose-based chiral stationary phase, J. Chromato. A. 955, 35-52 https://doi.org/10.1016/S0021-9673(02)00228-5
  24. Ching, C. B., B. G. Lim, E. J. D. Lee, and S. C. Ng (1993), Preparative resolution of praziquantel enantiomers by simulated counter-current chromatography, J. Chromato. A. 634, 215-219 https://doi.org/10.1016/0021-9673(93)83007-F
  25. Francotte, E. and P. Richert (1997), Applications of simulated moving-bed chromatography to the separation of the enantiomers of chiral drugs, J. Chromato. A. 769, 101-107 https://doi.org/10.1016/S0021-9673(97)00172-6
  26. Schutle, M., R. Ditz, R. M. Devant, J. N. Kinkel, F. Charton (1997), Comparison of the specific productivity of different chiral stationary phases used for simulated moving-bed chromatography, J. Chromato. A. 769, 93-100 https://doi.org/10.1016/S0021-9673(96)01002-3
  27. Seebach, D., M. Hoffmann, A. R. Sting, J. N. Kinkel, M. Schulte, Kusters, E. (1998), Chromatographic resolution of synthetically useful chiral glycine derivatives by high-performance liquid chromatography, J. Chromato. A. 796, 299-307 https://doi.org/10.1016/S0021-9673(97)01010-8
  28. Guest, D. W. (1997), Evaluation of simulated moving bed chromatography for pharmaceutical process development, J. Chromato. A. 760, 159-162 https://doi.org/10.1016/S0021-9673(96)00903-X
  29. Cavoya, E., M. F. Deltenta, S. Lehoucqb, Miggiano, D. (1997), Laboratory-developed simulated moving bed for chiral drug separations, Design of the system and separation of Tramadol enantiomers, J. Chromato. A. 769, 49-57 https://doi.org/10.1016/S0021-9673(96)00964-8
  30. Nagamatsu, S., K. Murazumi, S. Makino (1999), Chiral separation of a pharmaceutical intermediate by a SMB process, J. Chromato. A. 832, 55-65 https://doi.org/10.1016/S0021-9673(98)01004-8
  31. Pais, L. S., J. M. Loureiro, A. E. Rodrigues (1998), Separation of enantiomers of a chiral epoxide by simulated moving bed chromatography, J. Chromato. A. 827, 215-233 https://doi.org/10.1016/S0021-9673(98)00735-3
  32. Zenoni, G., M. Pedeferri, M. Mazzotti, and M. Morbidelli (2000), On-line monitoring of enantiomer concentration in chiral simulated moving bed chromatography, J. Chromato. A. 888, 73-83 https://doi.org/10.1016/S0021-9673(00)00486-6
  33. Pais, L. S., J. M. Loureiro, A. E. Rodrigues (2000), Chiral separation by SMB chromatography, Sep. Purif. Technol., 20, 67-77 https://doi.org/10.1016/S1383-5866(00)00063-0
  34. Heuer, C., E. Kuster, T. Plattner. A. Seidel-Morgenstern (1998), Design of the simulated moving bed process based on adsorption isotherm measurements using a perturbation method, J. Chromato. A. 827, 175-191 https://doi.org/10.1016/S0021-9673(98)00797-3