Performance Analysis of a Vehicle Disinfector Nozzles Used at Livestock Farm

축산 차량소독기의 노즐 성능 분석

  • Kim, W. (Dept. of Bio-Mechatronics, SungKyunKwan Univ.) ;
  • Lee, S. K. (Dept. of Bio-industry Mechanical Engineering, Kongju Univ.)
  • 김웅 (성균관대학교 바이오메카트로닉스학과) ;
  • 이승기 (공주대학교 생물산업기계전공)
  • Published : 2005.08.01

Abstract

The purpose of this study was to analyze the performance of vehicle disinfector nozzles using at the livestock farm. The nozzle of vehicle disinfectors was measured spraying rate and equality distribution ratio by pressures. The spraying rate of TK-I's nozzle was 1,605 ml/min at 3 MPa, TK-II's nozzle was 2,020 ml/min, JA's nozzle was 1,150 ml/min and IS's nozzle was 795 ml/min. The number of nozzles of TK-I's, TK-II's, JA's and IS's for reasonable spraying rate($25{\ell}/min$. at 3 MPa) was respectively 16, 13, 22 and 32 units. The equality distribution ratio of TK-I's nozzle by pressures was equalized and the nozzles of TK-II's, JA's and IS's was sprayed to the center or side more then other sides in the measured boxes.

축산 농가용 차량소독기의 노즐 분무성능과 균등분포율을 알아보고 적합성을 판단하고자 각 사별, 압력별 노즐 분무량을 측정하였다. 3 Mpa 분무압력에서 분무량은 TK사의 경우 1,605ml, TK-II 경우 2,020ml, JA사 노즐의 경우 1,150ml로 나타났으며, IS사의 경우 795ml로 나타났다. JA사의 경우 1,150 ml, IS사는 795 ml로 나타났다. 모든 압력에서 분무량은 TK-II, TK-I, JA 및 IS사 순으로 많았으며, TK-II사와 IS사간 분무량은 약 3배 차이를 보였다. 균등분포율을 알아보기 위한 압력별 측정결과는 모두 양 옆의 1, 2, 8, 9번 용기는 평균에 모자라는 분무량을 보였다. 그 외 3번 용기에서 7번 용기까지는 TK사의 경우 비교적 균일한 분무분포를 나타냈지만, JA사와 IS사의 경우 TK사 보다는 중앙이나 한쪽으로 분무량이 치우치는 경향을 나타냈다. 최적의 차량 소독기를 설계하기 위해서는 사용되는 노즐의 분사량, 균등분포율을 고려한 노즐 선택, 노즐 간격, 진행하는 차량의 속도 등을 우선적으로 고려하여 설계할 필요가 있을 것으로 판단되었다.

Keywords