DOI QR코드

DOI QR Code

Elastic-plastic Fracture Mechanics Analyses for Burst Pressure Prediction of Through-wall Cracked Tubes

관통균열 세관의 파열압력 예측을 위한 탄소성 파괴역학 해석

  • Published : 2005.10.01

Abstract

The structural and leakage integrity of steam generator tubes should be sustained all postulated loads with appropriate margin even if a crack is present. During the past three decades, for effective integrity evaluation, several limit load solutions have been used world-widely. However, to predict accurately load carrying capacities of specific components under different conditions, the solutions have to be modified by using lots of experimental data. The purpose of this paper is to propose a new burst pressure estimation scheme based on fracture mechanics analyses for steam generator tube with an axial or circumferential through-wall crack. A series of three dimensional elastic-plastic finite element analyses were carried out and, then, closed-form estimation equations with respect to both J-integral and crack opening displacement were derived through reference stress method. The developed engineering equations were utilized for structural integrity evaluation and the resulting data were compared to the corresponding ones fiom experiments as well as limit load solutions. Thereafter, since the effectiveness was proven by promising results, it is believed that the proposed estimation scheme can be used as an efficient tool for integrity evaluation of cracked steam generator tubes.

Keywords

References

  1. MacDonald, P.E., Shah, Y.N. and Ellison, P.G., 1996, 'Steam Generator Tube Failure,' NUREG/CR-6365, USNRC
  2. USNRC, 1976, 'Base for Plugging Degraded PWR Steam Generator Tubes,' Regulatory Guide 1.121
  3. Cochet, B. and Flesh, B., 1987, 'Crack Stability Criteria in Steam Generator Tubes,' 9th International Conference on SMiRT, Vol. D, pp. 413-419
  4. Yu, Y.J., Kim, J.H., Kim, Y. and Kim Y.J., 1994, 'Development of Steam Generator Tube Plugging Criteria for Axial Cracks,' International Journal of Pressure Vessels and Piping, Vol. 280, pp. 79-83
  5. Majumdar, S., 1999, 'Failure and Leakage Through Circumferential Cracks in Steam Generator Tubing during Accident Conditions,' International Journal of Pressure Vessels and Piping, Vol. 76, pp. 839-847 https://doi.org/10.1016/S0308-0161(99)00058-7
  6. Majumdar, S., Kasza, K., Franklin, J. and Muscara, J., 2000, 'Pressure and Leak-Rate Tests and Models for Predicting Failure of Flawed Steam Generator Tubes,' NUREG/CR-6664, USNRC
  7. Electric Power Research Institute, 1991, 'Steam Generator Tube Integrity Volume 1: Burst Test Results and Validation of Rupture Criteria (Framatome Data),' EPRI NP-6865-L
  8. Shim, D.J., Huh, N.S., Kim, Y.J. and Kim, Y.J., 2003, 'Plastic Limit Pressure Solutions for Cracked Pipes Using 3-D Finite Element Method,' Trans. Of the Korean Society of Mechanical Engineers, Vol. 27, No. 1, pp. 26-33 https://doi.org/10.3795/KSME-A.2003.27.1.026
  9. Shim, D.J., Kim, Y.J., Kim, Y.J., Hwang, S.S. and Kim, J.S., 2003, 'Plastic Limit Load Solutions for Circumferential Surface Cracked Cylinders Under Combined Loading,' Trans. Of the Korean Society of Mechanical Engineers, Vol. 27, No. 9, pp. 1469-1476 https://doi.org/10.3795/KSME-A.2003.27.9.1469
  10. Moon, S.I., Chang, Y.S., Kim, Y.J., Lee, J.H., Song, M.H. and Choi, Y.H., 2004, 'Assessment of Steam Generator Tubes with Multiple Axial Through-Wall Cracks,' Trans. Of the Korean Society of Mechanical Engineers, Vol. 28, No. 11, pp. 1741-1751 https://doi.org/10.3795/KSME-A.2004.28.11.1741
  11. Moon, S.I., Chang, Y.S., Kim, Y.J., Lee, J.H., Song, M.H., Choi, Y.H. and Hwang, S.S., 2004, 'Evaluation of Plastic Collapse Behavior for Multiple Cracked Structures,' Trans. Of the Korean Society of Mechanical Engineers, Vol. 28, No. 11, pp. 1813-1821 https://doi.org/10.3795/KSME-A.2004.28.11.1813
  12. Moon, S.I., Chang, Y.S., Kim, Y.J., Lee, J.H., Song, M.H., Choi, Y.H. and Kim, J.S., 2005, 'Development of Optimum Global Failure Prediction Model for Steam Generator Tube with Two Parallel Cracks,' Trans. Of the Korean Society of Mechanical Engineers, Vol. 29, No. 5, pp. 754-761 https://doi.org/10.3795/KSME-A.2005.29.5.754
  13. Shin, K.I., Park, J.H., Kim, H.D., Chung, H.S. and Choi, Y.H., 2004, 'Experimental and Analytical Study on Burst Pressure of a Steam Generator Tube with a T-type Combination Crack,' Trans. Of the Korean Society of Mechanical Engineers, Vol. 28, No. 2, pp. 158-164 https://doi.org/10.3795/KSME-A.2004.28.2.158
  14. Shin, K.I., Park, J.H., Jhung, M.J. and Choi, Y.H., 2004, 'Fracture Mechanics Analysis of Steam Generator Tubes after Shot Peening,' Trans. Of the Korean Society of Mechanical Engineers, Vol. 28, No. 6, pp. 732-738 https://doi.org/10.3795/KSME-A.2004.28.6.732
  15. ASME, 1998, 'Rules for Inservice Inspection of Nuclear Power Plant Components,' Sec.XI, ASME Boiler and Pressure Vessel Committee
  16. Ainsworth, R.A., 1984, 'The Assessment of Defects in Structures of Strain Hardening Materials,' Engineering Fracture Mechanics, Vol. 19, pp. 633-42 https://doi.org/10.1016/0013-7944(84)90096-1
  17. British Energy, 2001, 'R6: Assessment of the Integrity of Structures Containing Defects,' Revision 4
  18. Kanninen, M.F., Zahoor, A., Wilkowski, G., Abou-Sayed, I., Marshall, C., Broek, D., Sampath, S., Rhee, H. and Ahmad, J., 1982, 'Instability Predictions for Circumferentially Cracked Type 304 Stainless Steel Pipes under Dynamic Loading,' EPRI Report NP-2347, Electric Power Research Institute
  19. Miller, A. G., 'Review of Limit Loads of Structures Containing Defects,' Int. J. Pres. & Piping Vol. 32, pp.197-327 (1988) https://doi.org/10.1016/0308-0161(88)90073-7
  20. Webster, G.A. and Ainsworth, R.A., 1994, 'High Temperature Component Life Assessment,' Chapman and Hall
  21. Penny, R.K. and Marriot, D.L., 1995, 'Design for Creep,' Chapman and Hall
  22. Kim, Y.J, Shim, D.J., Huh, N.S. and Kim, Y.J., 2002, 'Plastic Limit Pressure for Cracked Tubes Using Finite Element Limit Analyses,' International Journal of Pressure Vessels and Piping, Vol. 79, pp. 321-330 https://doi.org/10.1016/S0308-0161(02)00031-5
  23. Kim, Y.J., Chang, Y.S., Moon, S.I., Kim, C.H. and Song, K.H., 2004, 'Development of Predictive Models for Failure of Flawed Steam Generator Tubes at Realistic Corrosion Environment,' KAERI/CM-778/2004
  24. ASTM, 2001, 'Standard Test Method for Measurement of Fracture Toughness,' E1820-01
  25. Mills, W.J., 1981, 'On the Relationship Between Stretch Zone Formation and the J-Integral for High Strain Hardening Materials,' Journal of Testing and Evaluation, Vol. 9, pp. 56-62 https://doi.org/10.1520/JTE10648J