DOI QR코드

DOI QR Code

Optimal Mixture Proportion for High Performance Concrete Incorporating Ground Granulated Blast furnace Slag

  • Choi Jae-Jin (Div. of construction and Environmental Engineering, Kongju National University) ;
  • Kim Eun-Kyum (Dept. of civil Engineering, Seoul National University of Technology) ;
  • Yoo Jung-Hoon (Rural Research Institute, Korea Agricultural & Rural infrastructure Corporation)
  • Published : 2005.06.01

Abstract

In this study, a mix design for self compacting concrete was based on Okamura's method and concrete incorporated just a ground granulated blast furnace slag. Replacement ratio of slag is in the range of $20-80\%$ of cement matrix by volume. For the optimal self compactability in mixture incorporating ground granulated blast furnace slag, the paste and mortar tests were first completed. Then the slump flow, elapsed time of 500mm slump flow, V funnel time and filling height by U type box were conducted in concrete. The volume of coarse aggregate in self compacting concrete was in the range of $50-60\%$ to the solid volume percentage of coarse aggregate. Finally, the compressive and splitting tensile strengths were determined in the hardened self compacting concrete incorporating ground granulated blast furnace slag. From the test results, it is desirable for self compacting concrete that the replacement of ground granulated blast furnace slag is in the range of $40-60\%$ of cement matrix by volume and the volume of coarse aggregate to the solid volume percentage of coarse aggregate with a limit of $55\%$.

Keywords

References

  1. Ozawa, K., Maekawa, K., and Okamura, H., 'Development of the High Performance Concrete', Proceedings of the Japan Concrete Institute, Vol.11, No.1, 1989, pp.699-704
  2. Sasaki, S. and Kagaya, M., 'Consideration on Filling Characteristics of SCC Based on Fluidity of Cement Paste Component', Proceedings of the Second International Symposium on Self-Compacting Concrete, Tokyo, Japan, 2001, pp.319-328
  3. Grunewald, S. and Walraven, J., 'Parameter-study on the Influence of Steel Fibers and Coarse Aggregate Contents on the Fresh Properties of Self-compacting Concrete', Cement and Concrete Research, Vol.31, No.12, 2001, pp.1793-1798 https://doi.org/10.1016/S0008-8846(01)00555-5
  4. Persson, B., 'A Comparison between Mechanical Properties of Self-compacting Concrete and the corresponding Properties of Normal Concrete', Cement and Concrete Research, vol.31, No.2, 2001, pp.193-198 https://doi.org/10.1016/S0008-8846(00)00497-X
  5. Gram, H. and Piiparinen, P., 'Study of Material Properties of SCC by Mortar Tests', Proceedings of the Third International RILEM Symposium on Self-Compacting Concrete, Reykjavik, Iceland, 2003, pp.305-310
  6. Domone, P., 'The Slump Flow Test for High-workability Concrete', Cement and Concrete Research, Vol.28, No.2, 1998, pp.177-182 https://doi.org/10.1016/S0008-8846(97)00224-X
  7. EFNARC, Specification and Guidelines for Self-Compacting Concrete, EFNARC, 2002
  8. Japanese Society of Civil Engineering, The Problem and the Present of Technology about High Flowing Concrete, Concrete Engineering Series, No.15, Tokyo, 1996
  9. Okamura, H., Maekawa, K., and Ozawa, K., High Performance Concrete, Gihoudou Pub., Tokyo, 1993
  10. Japanese Society of Civil Engineering, Guide to Construction of High Flowing Concrete, Gihoudou Pub., Tokyo, 1998
  11. Okamura, H. and Ouchi, M., 'Self Compacting Concrete', Journal of Advanced Concrete Technology, Vol.1, No.1, 2003, pp.5-15 https://doi.org/10.3151/jact.1.5