Evaluation of Extraction Mode for SVE Process by On-Line Monitoring System

온라인 모니터링에 의한 디젤오염토양의 토양증기추출 공정시 추출모드 평가

  • Park, Joon-Seok (Department of Environmental Engineering, Samcheok National University) ;
  • Kim, Seung-Ho (Department of Environmental Engineering, Samcheok National University) ;
  • Park, Young-Goo (Department of Environmental Engineering, Samcheok National University)
  • 박준석 (국립삼척대학교 환경공학과) ;
  • 김승호 (국립삼척대학교 환경공학과) ;
  • 박영구 (국립삼척대학교 환경공학과)
  • Received : 2003.10.29
  • Accepted : 2003.12.04
  • Published : 2003.12.30

Abstract

This study was performed to evaluate effect of extraction mode on SVE efficiency for fuel-contaminated soil. A gas station was selected for this study. As a result of pressure test in well head, soil texture of contaminated site under the gas station was very different from site to site. SVE system was operated in intermittent mode (1hr extraction / 3hr rest) or continuous mode. Capacity of air blower was $1m^3/min$. Extration mode test was conducted in two severe contaminated sites. In both two sites, cumulative TPHgas mass of intermittent extraction mode was higher than that of continuous mode. Considering long term operation of SVE in a field, in general, it was thought that intermittent extraction mode was effective in view of vaporized TPHgas mass and electrical cost.

본 연구에서는 유류로 오염된 현장 주유소를 대상으로 토양증기추출 공정 적용시 연속추출과 간헐추출 운전의 효율성을 검토하였다. 공기주입 후 압력을 측정한 결과 동일 조건에서도 공기주입정 헤드(head) 압력이 상이하게 나타나 실험부지내 토양이 매우 불균일하다는 것을 알 수 있었다. 간헐식은 1시간 가동 후 3시간 정지시켰으며, 연속식은 50분 가동 후 10분 휴지하는 것을 연속추출한 것으로 가정하였다. 송풍기의 용량은 $1m^3/min$이었다. 추출모드의 영향실험은 오염농도가 심한 두 지점을 선정하여 실시하였으며, 48시간 동안 온라인 모니터링으로 측정한 TPHgas 농도를 적산하여 비교한 결과 1시간 가동 후 3시간 휴지한 간헐추출모드가 연속추출모드보다 높게 나타났다. 일반적으로 토양증기추출 공정이 장기간 가동된다는 점을 고려한다면 오염가스 휘발량, 전력비용, 그리고 시설의 감가상각비 등에서 볼 때 간헐추출모드로 운전하는 것이 연속추출모드 보다 더 유리할 것으로 판단된다.

Keywords