LC/MS/MS를 이용한 sildenafil 및 그 유사체 분석

Analysis of Sildenafil and its Analogues by LC/MS/MS

  • 명승운 (한국과학기술연구원 도핑콘트롤센터) ;
  • 박서희 (한국과학기술연구원 도핑콘트롤센터) ;
  • 조현우 (경기대학교 이과대학 화학과)
  • Myung, Seung-Woon (Doping Control Center, Korea Institute of Science and Technology) ;
  • Park, So-Hee (Doping Control Center, Korea Institute of Science and Technology) ;
  • Cho, Hyun-Woo (Department of Chemistry, KyongGi University)
  • 투고 : 2003.08.07
  • 심사 : 2003.10.16
  • 발행 : 2003.12.25

초록

LC/MS/MS를 이용하여 발기부전 (impotence) 치료제인 sildenafil 및 유사체인 homosildenafil, vardenafil, tadalafil을 분석하는 방법을 확립하였다. 이온화 방법으로는 electrospray ionization (ESI)와 atmospheric pressure chemical ionization (APCI) 방법을 사용하였으며 최대 감도와 재현성을 나타내는 조건을 찾기 위하여 여러 가지 파라미터를 변화시켜서 비교하였다. MRM (multiple reaction monitoring)을 위한 적절한 생성이온 (product ion)을 얻기 위하여 ESI 방법에서는 capillary voltage, cone voltage, extractor, entrance, RF lens를 변화시켰으나 전구이온 (precursor ion)을 제외한 뚜렸한 토막이온 (fragment ion)은 생성되지 않았다. 한편, APCI 방법의 경우 entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, desolvation gas를 변화시켰을 때 다른 파라미터들의 변화에 따른 전구이온을 제외한 product ion 생성 패턴의 변화는 감지되지 않고 단지 RF lens 조건의 변화에서 precursor ion을 비롯한 토막이온들의 생성과 더불어 S/N의 증가로 인한 검출 한계의 향상이 나타났다. HPLC에서의 최적 분리 조건과 질량 분석기에서 최대 감도를 나타내는 이동상 조건도 조사되었는데 10 mM ammonium formate (pH 4.8):acetonitrile=70:30 의 등용매 용리조건이 좋은 감도를 나타내었으며, 최적의 방법인 ESI-MRM 방법에서 검출한계 (S/N>5)는 sildenafil은 $0.10{\mu}g/mL$, homosildenafil은 $0.025{\mu}g/mL$, vardenafil은 $0.025{\mu}g/mL$ 그리고 tadalafil은 $0.25{\mu}g/mL$이었다.

By LC/MS/MS, the analytical method of sildenafil and its analogues (homosildenafil, vardenafil and tadalafil) used as used medical treatment of impotence was established. electrosprary ionization (ESI) and atmospheric pressure chemical ionization (APCI) as a ionization method were applied. Several parameter were varied and the sensitivity and reproducibility were compared. In LC/ESI-MS method, capillary voltage, cone voltage, extractor, entrance and RF lens to create appropriate productr ions for multiple reaction monitoring (MRM) were variable parameter, but the formation of the other product ions except the precursor ion could not detect. And the value of entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, and desolvation gas in APCI mode were varied, only the creation pattern of fragment ions by the change of RF lens value were detected, and the limit of detection was decreased due to the increase of S/N. Ten millimole ammonium formate (pH 4.8):acetonitrile=70:30 by isocratic elution in HPLC system was shown the maximum sensitivity in MS, the detection limit of sildenafil, homosildenafil, vardenafil and tadalafil obtained by ESI-MRM were 0.10, 0.025, 0.025, and $0.25{\mu}g/mL$ at S/N>5, respectively.

키워드

참고문헌

  1. Graham N. MAw, Charlotte M. N. Allerton, Eugene Gbekor, William A. Million, Bioorganic & Medicinal Chemistry Letters, 13, 1425-1428(2003).
  2. R. Hyland, E. G. H. Roe, B. C Jones, D. A. Smith, Br. J. Clin. Pharmacal., 51, 239-248(2000).
  3. J. D. H. Cooper, D. C. Muirhead, J. E. Taylor, R. T. Baker, J. Chromatogr. B, 701, 87-95(1997).
  4. C. K. Jeong, H. Y. Lee, M. S. Jang, W. B. Kim, H. S. Lee, J. Chromatogr. B,752, 141-147(2001).
  5. J. Law, T. W. Chang, J. Chromatogr. B, 765, 161-166(2001).
  6. K. Saisho, K. S. Scott, S. Morimoto, Y. Nakahara, BioI. Pharm. Bull, 24, 1384-1388(2001).
  7. J. J. B. Nevado, J. R. Flores, G. C. Penalvo, N. R. Farinas, J. Chromatogr. A, 953, 279-286(2002).
  8. W. Weinmann, M. Bohnert, A. Wiedemann, M. Renz, N. Lehmann, S. Pollak, Int. J. Legal Med., 114, 252-258(2001)
  9. V. Dumesrre-Toulet, V. Cifimele, S. Gromb, T. Beloussoff, Lavault, B. Ludes, P. Kintz, Forensic Sci. Int. 126, 71-76(2002).
  10. A. Eerkes. T. Addision. T.A ddison, W. Naidoge, J. Chromatogr. B 768, 277-284(2002).
  11. J. Kim, H. Y. Ji S. Kim, H. W. Lee, S.-S. Lee, D. S. Kim, M. Yoo, W. B. Kim, H. S. Lee, J. Pharmaceutical and Biomedical Analysis, 32, 317-322(2003).
  12. Angela Eerkes, Tom Addison, Weng Naidong, J. Chromatography B, 768, 277-284(2002).
  13. H. Porst, H. Padma-Nathan, F. Giuliano, G. Anglin, L. Varanese, R. Rosen, Urology, 62, 121-125(2003).
  14. c.-S. Lin, Z.-c. Xin, G. Lin, T. F. Lue, Urology, 61, 685-691(2003).
  15. 김택제, 명승운, 조현우, 김명수, '실용적인 기체.액체 크로마토그래피와 질량분석법', 353-367, 자유 아카데미, 2002.