Trends of Volitile Organic Compounds in the Ambient Air of Yeosu Industrial Complex

여수산단 대기 중 휘발성유기화합물질 농도 경향

  • Jeon, Jun-Min (Dept. of Environmental Engineering, Suncheon First College) ;
  • Hur, Dang (Dept. of Environmental Engineering, Suncheon First College) ;
  • Kim, Dong-Sul (Air Pollution Lab., School of Environment & Applied Chemistry, Kyung Hee University)
  • 전준민 (순천제일대학 환경과) ;
  • 허당 (순천제일대학 환경과) ;
  • 김동술 (경희대학교 환경응용화학부 대기오염연구실)
  • Published : 2003.12.01

Abstract

The concentrations of volatile organic compounds (VOCs) in the ambient air were measured at three sites (Samil-dong, SRO and EFMC) in Yeosu industrial complex during September 2000 to August 2001. Air samples were collected for 24 hours in Silicocan canister (6l) with constant flow samplers every 6 days and analyzed using a cryogenic preconcentration system and a GC/MS. At each site, we identified 35 species known as on both the carcinogenic and mutagenicity by the EPA US (TO-14 manual). No relationship was found between YOCs concentration at three sampling points. Furthermore, the result shows that there appears to be a variety distribution of the concentration. BTX, vinyl chloride and high concentrations of 1,2-dichloroethane were observed at the sampling sites. Especially, high concentration of toxic VOCs, such as vinyl chloride, chloroform, 1,2-dichloroethane and benzene were shown at environmental facilities management cooperation (EMFC) site. They seem to be emitted from the facility of wastewater treatment in Yeosu industrial complex. It was difficult to tell the seasonal variation of total VOCs concentration. Nevertheless, the concentration in winter was typically higher than in summer The concentrations of toxic VOCs contents in Yeosu industrial complex were generally lower than those in Ulsan complex, although those were similar or less than in Seoul and Daegu. Whereas, toluene and styrene emitted from Yeosu industrial complex were higher than those of Edmonton industrial complex in Canada. Especially, toluene was third times higher than those observed from Texas, USA.

Keywords

References

  1. 김기현, 김민영, 오상인, 윤중섭, 이강웅 (2001) 난지도를 중심으로 한 대기 중 BTEX 성분의 농도분포 특성에 대한 연구, 한국대기환경학회지, 17(6), 463-474
  2. 김미현, 박상곤, 백성옥(2002) 대도시 교통밀접지역 도로변 대기 중 휘발성유기화합불의 농도분포 특성, 한국대기환경학회지, 18(2), 113-126
  3. 김용표, 이종훈, 진현철, 문길주(1997) 여천공단 대기 중의 입자상 및 기체상 이온성분과 유기화합물의 농도, 한국대기보전학회지, 13(4),269-284
  4. 김영성, 송철한, 심상규, 김용표, 문길주(1998) 여천공업단지 봄, 가을 대기 중 휘발성 유기화합물 농도 비교 연구, 한국대기보전학회지,14(2), 153-160
  5. 김영성 (1999) 산업단지 대기질 관리, HAP인가 VOC 인가?,한국대기환경학회지, 15(4 ), 513-517
  6. 나광삼, 김용표, 진현철, 문길주(1998) 울산대기 중의 입자상, 기체상 물질의 수용성 이온성 분과 휘발성 유기화합물의 농도, 한국대기보전학회지, 14(4), 281-292
  7. 백성옥(2000) 특정대기유해물질의 대기오염실태 조사연구, 한국대기환경학회 보고서
  8. 백성옥, 김성렬, 김배갑(2002) 도시 대기 중 휘발성 유기화합물의 농도변동 및 영향인자, 대한환경공학회지, 24(8),1391-1404
  9. 양성봉(1998) 화학공장 VOCs진단 및 저감기술연구, 울산지역환경기술센터 보고서
  10. 여수화력발전처(2002) 자동기상측정망 자료
  11. 전준민, 허 당, 김동술 (2002) Canister와 GCIMSD를 이용한 대기 중 VOCs 분석시스템의 정도관리 (QC),한국대기환경학회지, 18(6),527-538
  12. 한국산업단지공단(2001), 통계자료
  13. KIST(1996) 여천공단 주변마을 환경영향 및 대책에 관한 연구,단행본
  14. NIER (1997) 여천공단 환경오염대책 마련을 위한 오염실태 정밀조사 사업,단행본
  15. CARB(1991) Ambient toxics air contaminant monitoring program, California Air Resources Board, P.O.Box 2815, Sacramento, CA 95812
  16. Cheng, L. et al. (1997) Seasonal variations of volatile organic compounds in Edmonton, Alberta, Atmos. Environ.,31(2),239-246
  17. Derwent, R.G. et al. (2000) Analysis and Interpretation of Continuous Hourly Monitoring Data for 26 C2-C8 Hydrocarbons at 12 United Kingdom Sites During 1996, Atmos. Environ., 34, 297- 312
  18. Harley, R.A. and G.R. Cass (1995) Modeling the atmospheric concentrations of individual volatile organic compounds, Atmos. Em iron., 29, 905-922
  19. Maltoni, e. et al. (1981) Carcinogenicity bioassays of vinyl chloride monomer; A model of risk assessment on an experimental basis, Environ. Heal. Perspec., 41, 3-29
  20. MOEE (1996) 1995 Air Quality Data Summary, City of Nanticoke, Ontario, Canada
  21. Mohan Rao, A.M., G.G. Pardit, P. Sain, S. Sharma, T.M.Krishnamoorthy, and K.S.V. Nambi (1997) Nonmethane hydrocarbons in industrial locations of Bombay, Atmos. Environ., 31(7), 1077-1085 https://doi.org/10.1016/S1352-2310(96)00266-X
  22. Na, K.S. and Y.P. Kim (2001) Seasonal characteristics of ambient volatile organic compounds in Seoul, Korea, Atmos. Environ., 35, 2603-2614
  23. NCI(1978) Bioassay of I, 2-dichloroethane for possible carcinogenicity, NCI-TR-55, DEHW (NIH), 78-1361
  24. Parrish, D.D. and F.e. Fehsenfeld (2000) Methods for gasphase measurements of ozone, ozone precursors and aerosol precursors, Atmos. Environ., 34, 1921-1957
  25. Schaich, J.R (1991) Estimate fugitive emissions from process equipment, Chemical Engineering Progress, 31-35
  26. Singh, H.B., L. Salas, W. Viezee, B. Sitton, and R Ferek (1992) 'Measurement of Volatile Organic Chemicals at Selected Sites in California', Atmos. Environ., 26A(16), 2929-2946
  27. Thijsse, T.R., M.G.M. Roemer, and R.F. van Oss (1999) Trends in large-scale VOC concentrations in the Southern Netherlands between 1991 and 1997, Atmos. Environ., 33(23), 3803-3812 https://doi.org/10.1016/S1352-2310(98)00421-X
  28. TNRCC (1994) Community Air Toxics Monitoring Program Report, U.S Texas Natural Resource Conservation Commission, USA
  29. UK DOE (1994b) Expert Panel on Air Quality Standards Benzene, HMSO, London
  30. US EPA (1983) Health assessment document for toluene, EPA-600/8-82-008F
  31. US EPA (1996) Integrated Risk Information System (IRIS)
  32. US EPA (1997) Compendium Method TO-14A - Determination of Volatile Organic Compounds (VOCs) in Ambient Air Using Specially Prepared Canisters With Subsequent Analysis By Gas Chromatography, Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air, 2nd ed., EPA/625/R-96/010b
  33. US EPA (1999) Compendium method TO- 15- Determination of Volatile Organic Compounds (VOCs) in Air Collected in Specially- Prepared Canisters And Analyzed By Gas Chromatography/Mass Spectrometry (GC/MS), Compendium method for the Determination of Toxic Organic Compounds in Ambient Air, 2nd ed., EPA/625/R -96/010b
  34. US EPA (1999) National Air Toxics Program
  35. Wadden, R.A. and P.A. Scheff (1994) Receptor Modeling of VOCs; II. Development of VOC Control Functions for Ambient Ozone, Atmos. Environ., 28(15), 2507-2521 https://doi.org/10.1016/1352-2310(94)90401-4
  36. WHO (1987) Air Quality Guidelines for Europe, WHO Tub, European Series. 23
  37. WMO (1985) Atmospheric ozone 1985 World Meteorological Organization, Global Ozone Research and Monitoring Project-report No.20