Abstract
This reserch was focused upon experimental study for wastewater reuse and conducted to evaluate optimum operating conditions of rapid filtration process such as filter flow rate, filtration time and backwashing condition for reuse of secondary-treated effluent using the pilot plant installed in real wastewater treatment plant. Also, the experiment on treatment char-acteristics of coagulant-added activated sludge process was performed to compare with activated sludge succeeded to rapid filtration. As the filtration velocity was 100m/day, the filtration time of the rapid filter connected with activated sludge system was revealed to 40 hours. Backwashing of filter was conducted by water wash and air scour. The optimum backwashing time and backwash flow rate were 10min and 10LPM, respectively. The quantity of backwashing water of the rapid filter was about 2% of total treated water.
하수 처리수의 재이용을 위하여 표준활성슬러지법에 의한 생물학적 처리 후 최종침전지 유출수를 급속여과공정으로 처리하기 위한 Pilot Plant 실험연구가 수행되었다. 또한, 활성슬러지와 연계된 급속여과공정과 포기조 후단에 응집제를 주입하는 활성슬러지 이후 급속여과 처리하는 공정과의 비교 실험도 행해졌다. 최종침전지 유출수를 급속여과공정으로 처리한 경우 여과속도는 100m/day, 여과지속시간은 40시간 이하로 운전하는 것이 타당한 것으로 나타났으며, 여과지의 역세척 주기는 여과속도 100m/day일 때 40시간에 1회 정도가 되었다. 여과지 역세척 시 역세척 방법은 공세 1분, 공세+수세 30초, 수세 1분, 공세·수세 2분, 수세 3분, 안정 30초, 배수 10분의 순으로 행하는 것이 효과적이었으며, 수세속도는 10LPM으로 전체 여과수량의 2%정도였다. 표준활성슬러지 시스템에 의한 2차 처리수를 잡용수로 재이용 하기 위해서는 폭기조 후단에 응집제를 첨가하여 여과 공정을 후속공정으로 하는 시스템으로 유용하게 사용할 수 있을 것으로 판단된다.