References
- Arbogast R. and Arbogast C.J., 'The carbon copy II - From concept to application,' Journal of Prosthetics and Orthotics International, Vol. 18, pp. 92-97, 1994
- Burgess E.M., Poggi D.A., Hittenberger J.H., Zetttl D.E., Moeller K.L., Carpenter K.L., and Forsgen S.M., 'Development and preliminary evaluation of the VA Seattle foot,' Journal of Rehab. Res. Dev., Vol. 22, pp. 75-84, 1985 https://doi.org/10.1682/JRRD.1985.07.0075
- Hsu M.J., Nielsen D.H., Yack H.J., and Shurr D.G., 'Physiological measurements of walking and running in people with transtibial amputations with 3 different prostheses,' Journal of Orthop. Sports Phys. Ther., Vol. 29(9), pp. 526-33, 1999 https://doi.org/10.2519/jospt.1999.29.9.526
- van der Linden M.L., Solomonidis S.E., Spence W.D., Li N., and Paul J.P., 'A methodology for studying the effects of various types of prosthetic feet on the biomechanics of trans-femoral amputee gait,' Journal of Biomech., Vol. 32, pp. 877-889, 1999 https://doi.org/10.1016/S0021-9290(99)00086-X
- Macfarlane P.A., Nielsen D.H., Sehurr D.G., and Meier K., 'Gait comparisons for below-knee amputees using a Flex-Foot versus a conventional prosthetic foot,' Journal of Prosthetics and Orthotics, Vol.3, pp. 150-161, 1991 https://doi.org/10.1097/00008526-199100340-00008
- Perry J., Boyd L.A., Rao S.S., and Mulroy S.J., 'Prosthetic weight acceptance mechanics in transtibial amputees wearing the Single Axis, Seattle Lite, and Flex Foot,' IEEE Trans. Rehab. Eng., Vol. 5(4), pp. 283-9, 1997 https://doi.org/10.1109/86.650279
- Prince F., Winter D.A., Sjonnensen G., Powell C., and Wheeldon R.K., 'Mechanical efficiency during gait of adults with transtibial amputation: a pilot study comparing the SACH, Seattle, and Golden-Ankle prosthetic feet,' Journal of Rehab. Res. Dev., Vol. 35(2), pp. 177-85, 1998
- Rao S.S., Boyd L.A., Mulroy S.J., Bontrager E.L., Gronley J.K., and Perry J., 'Segment velocities in normal and transtibial amputees: prosthetic design implications,' IEEE Trans. Rehab. Eng., Vol. 6(2), pp. 219-26, 1998 https://doi.org/10.1109/86.681188
- Tanimoto Y., Takechi H., Nagahata H., and Yamamoto H., 'The study of pressure distribution in sitting position on cushions for patients with SCI,' Proceed. IEEE Instrument Measurement, Vol. 77, pp. 219-224, 1998 https://doi.org/10.1109/IMTC.1998.679761
- 재활공학연구소, '통합제어형 하지의지의 개발,' 선도기술/의료공학 기술개발사업 보고서, 보건복지부, 1999
- Polliack A.A., Lamsberger S., McNeal D., and Ayyappa E., 'Improving socket fit and function: the potential of interface pressure and other measures at the socket,' 2nd AAOP annual metting, pp.35-36, 1997
- Conti S.F., Martin R.L., Chaytor E.R., Hughes C., and Lettrell L., 'Plantar pressure measurements during ambulation in weight bearing conventional short leg casts and total contact casts', Foot & Ankle International, Vol. 17(8), pp. 464-469, 1996 https://doi.org/10.1177/107110079601700805
- Mooney V., 'Above-Knee Amputations,' American Academy of Orthopaedic Surgeons: AlIn of Limb Prosthetics, C.V. Mosby, St. Louis, 1981
- Waters R.L., Perry J., Antonelli D., and Mislop H., 'Energy Cost of Walking of Amputees: The Influence of Level of Amputation,' Journal of Bone and Joint Surg., Vol. 58A, pp. 4246, 1976
- Gottschalk F.A., Kourosh S., Stills M., McClellan B., and Roberts J., 'Does Socket Configuration Influence the Position of the Femur in Above-Knee Amputation?,' Journal of Prosthetics and Orthotics, Vol. 2, pp. 94-102, 1990
- Schall S.R., Dsida S.R., Slemker T.C., 'Socket science: Technology transforms transfemoral prosthetics,' BioMechanics, September, 1997