Abstract
In the past, safety assessment on the site of Ulchin Nuclear Power Plants against tsunamis was carried out with probable maximum earthquake magnitude and related tsunamigenic fault parameters. Recently, however, based on the seismic gap theory, some seismologists warned about earthquakes of larger magnitudes than had been expected. In this study, we revaluated tsunami risk with a finite difference model based on linear and nonlinear shallow water equations. Firstly, we simulated the\`83 tsunami and compared the calculated water surface profile with the observed wave heights. Secondly, we evaluated the rise and drop of sea water level at the site of Ulchin Nuclear Power Plant with fault parameters of the past '83, '93 tsunamis and some dangerous faults. Finally, we showed that the cooling water intake facility of Ulchin Nuclear Power Plants would be safely operated in disastrous tsunamis.
과거, 울진원전 부지의 지진해일에 대한 안전성 평가는 가상최대 지진규모와 그에 상응하는 단층 파라미터를 이용하여 수행되었으나. 최근 지진공백역 이론에 근거하여, 과거 평가 규모 이상의 지진발생 가능성이 지진학자들에 의하여 제기되고 있다. 본 연구에서는 선형·비선형천수방정식 기반의 유한차분법을 이용하여 지진해일 안전성을 재평가하였다. 먼저, '83년 지진해일을 모의하고 이를 동해안 임원항의 최고 범람 수위와 비교하였다. 다음으로 '83년, '93년 지진해일과 위험 단층으로 분류되고 있는 5개 지진공백역 단층에 대하여 울진원전부지 도수로에서의 수위 상승과 저하를 계산하여, 울진원전이 평가대상 단층으로 의한 지진해일 발생시에도 필요 냉각수의 취수가 가능함을 보였다.