DOI QR코드

DOI QR Code

Determination of Research Octane Number using NIR Spectral Data and Ridge Regression


Abstract

Ridge regression is compared with multiple linear regression (MLR) for determination of Research Octane Number (RON) when the baseline and signal-to-noise ratio are varied. MLR analysis of near-infrared (NIR) spectroscopic data usually encounters a collinearity problem, which adversely affects long-term prediction performance. The collinearity problem can be eliminated or greatly improved by using ridge regression, which is a biased estimation method. To evaluate the robustness of each calibration, the calibration models developed by both calibration methods were used to predict RONs of gasoline spectra in which the baseline and signal-to-noise ratio were varied. The prediction results of a ridge calibration model showed more stable prediction performance as compared to that of MLR, especially when the spectral baselines were varied. . In conclusion, ridge regression is shown to be a viable method for calibration of RON with the NIR data when only a few wavelengths are available such as hand-carry device using a few diodes.

Keywords

References

  1. Handbook of Near-Infrared Analysis Burns, D. A;Ciurczak, E. W
  2. Multivariate Martens, H;Naes, T. M
  3. Anal. Chem v.54 Brown, C. W;Lynch, P. F;Obremski, R. J;Lavery, D. S
  4. Cereal Chem. v.61 Norris, K. H;Williams, P. C
  5. Anal. Chem. v.58 Mark. H
  6. Anal. Chem. v.55 Wetzel, D. L
  7. Appl. Spec. Rev v.22 no.4 Stark, E;Luchter, K;Margoshes, M
  8. Applied Linear Statistical Models Neter, J;Kutner, M. H;Nachtsheim, C. J;Wasserman, W;Richard, D(ed.)
  9. Applied Regression Analysis Rawing, J. O
  10. Applied Regression Analysis Rawing, J. O
  11. Anal. Chem. v.61 Kelly, J. J;Barlow, C. H;Jinguji, T. M;Callis, J. B
  12. U.S. Patent v.506 Maggard, S. M
  13. American Society for Testing and Materials Annual Book of ASTM Standards, Method D2699
  14. Comm. in Stat. Theor. Meth v.14 Lee, T;Campbell, D
  15. K. Comm. in Stat v.4 Hoerl, A;Kennard, R;Baldwin, K

Cited by

  1. A New Genetic Algorithm Applied to the near Infrared Analysis of Gasolines vol.12, pp.1, 2004, https://doi.org/10.1255/jnirs.411
  2. Determination of Octane Number of Gasoline Using Near Infrared Spectroscopy and Genetic Multivariate Calibration Methods vol.23, pp.9, 2001, https://doi.org/10.1081/lft-200035547
  3. Spectral Range Optimization for the Near-Infrared Quantitative Analysis of Petrochemical and Petroleum Products: Naphtha and Gasoline vol.60, pp.8, 2006, https://doi.org/10.1366/000370206778062219
  4. Moment combined partial least squares (MC-PLS) as an improved quantitative calibration method: application to the analyses of petroleum and petrochemical products vol.131, pp.5, 2001, https://doi.org/10.1039/b515761g
  5. Applications of Near-Infrared Spectroscopy in Refineries and Important Issues to Address vol.42, pp.3, 2001, https://doi.org/10.1080/05704920701293778
  6. Functional Kernel-Based Modeling of Wavelet Compressed Optical Emission Spectral Data: Prediction of Plasma Etch Process vol.10, pp.3, 2001, https://doi.org/10.1109/jsen.2009.2038569
  7. Supervised principal components: a new method for multivariate spectral analysis vol.27, pp.12, 2001, https://doi.org/10.1002/cem.2558
  8. QSPR Models for Octane Number Prediction vol.2014, pp.None, 2001, https://doi.org/10.1155/2014/520652