전기철도시스템에서 직격뇌에 대한 가공지선의 내뇌효과

Shielding Effects of an Overhead Ground Wire in the Electric Railway Systems due to Direct Lightning Strokes

  • 발행 : 2001.05.01

초록

본 논문은 전기철도시스템 고압 배전선로에서 직격뇌에 의한 가공지선의 영향에 대해서 설명하였다. EMTP를 사용하여 가공지선과 보안기의 영향을 정량적으로 분석하였다. 또한 전차선로의 구조변경과 피격전류의 크기, 파미값의 변화에 대한 영향도 평가하였다. 분석결과 기존 시스템에 가공지선의 설치는 전기철도시스템 고압 배전선로에 유도되는 피격전압을 억제하는 효과가 있음을 입증하였다.

This paper describes the effect of an overhead ground wire in Power distribution lines of electric railways due to direct lightning strokes. Using the EMTP, the effects of an overhead ground wire and a s-horn are analyzed quantitatively. Also, the influences of the structure of electric railways and of peak value and time-to-half value of a stroke currents are evaluated. The analysis show that in installation of in overhead ground wire into a existing railway system, the induced voltage in power distribution lines of electric railways in suppressed.

키워드

참고문헌

  1. IEEE Transactions on Power Delivery v.1 no.1 Distribution Surge Arrester Behavior due to Lightning Induced Voltages S.Yokoyama
  2. IEEE Transactions on Power Delivery v.4 no.4 Experimental Study of Response of Power Distribution Lines to Direct Lightning Hits S.Yokoyama(et al.)
  3. ICEE'99 Lightning protection for power distribution lines and effects of lightning protective devices S.Yokoyama(et al.)
  4. 日本電氣學會論文誌,電學論B v.116 no.9 配電線直擊雷に對する避雷器處理エネルギ一の檢討 -雷擊位置およひ避雷器施設位置の影響- 中田一夫(外)
  5. IEEE Transactions on Power Delivery v.12 no.4 Energy Absorption of Surge Arresters on Power Distribution Lines due to Direct Lightning Strokes -Effects of an Overhead Wire and Installation Position of Surge Arresters K.Nakada(et al.)
  6. 電力と鐵道 v.19 no.8;172 架空地線の避雷效果 電力中央硏究所.耐電設計基準委員會
  7. 電力と鐵道 v.19 no.9;173 續,架空地線の避雷效果 電力中央硏究所.耐電設計基準委員會
  8. 鐵道と電氣技術 v.4 no.12 電氣鐵道システムにている耐雷設計技術 (4) 岡井政彦
  9. Transactions of the Institute of Electrical Engineers of Japan B-A Publication of Power and Energy Society v.117-B no.4 Lightning surge overvoltages on a feeding system of a MAGLEV train H.Muragishi(et al.)
  10. 뇌와 고도정보화사회 곽희로(외)
  11. EPRI EL-4202,Research Project 2149-1,Final Report Electromagnetic Transients Program (EMTP) Primer EPRI
  12. 한국철도기술연구원 보고서 전차선로 회로정수 측정 및 보호회로 최적화 방안 연구
  13. 한국전력공사 기술연구원 최종보고서 KRC-84S-S17 IKL도 작성 및 배전선 내뢰설계