A STUDY ON TOOTHBRUSH ABRASION OF CERVICAL RESTORATIVE MATERIALS

치경부 심미수복재의 잇솔질 마모에 관한 연구

  • Baik, Byeong-Ju (Department of Pediatric Dentistry and Institute of Oral Bioscience, School of Dentistry, Chonbuk National University) ;
  • Yang, Jeong-Sook (Department of Pediatric Dentistry and Institute of Oral Bioscience, School of Dentistry, Chonbuk National University) ;
  • Lee, Doo-Cheol (Department of Pediatric Dentistry and Institute of Oral Bioscience, School of Dentistry, Chonbuk National University) ;
  • Kim, Jae-Gon (Department of Pediatric Dentistry and Institute of Oral Bioscience, School of Dentistry, Chonbuk National University)
  • 백병주 (전북대학교 치과대학 소아치과학교실) ;
  • 양정숙 (전북대학교 치과대학 소아치과학교실) ;
  • 이두철 (전북대학교 치과대학 소아치과학교실) ;
  • 김재곤 (전북대학교 치과대학 소아치과학교실)
  • Published : 2001.02.28

Abstract

This study was performed to evaluate the toothbrush abrasion characteristics of seven commercially available light-cured cervical restorative materials one resin-modified glass-ionomer material(Fuji II LC) three polyacid-modified composites(Compoglass, Dyract, F2000), and three light-cured composites(Heliomolar, Palpique Estelite, UniFil F). All samples were stored in distilled water at $37^{\circ}C$ for 10 days. 2.0N of weight was loaded during the test and the abraded surfaces were examined with profilometer and SEM after 100,000 cycles. The results obtained were summarized as follows; 1. The highest hardness value of 79.7 was observed in the FT group and the lowest value of 20.0 was observed in the HM group. Results of Tukey test showed that an overall significant difference was indicated except the CG and DR groups(p<0.05). 2. The highest surface roughness was observed in the FL group and the lowest was observed in the UF group. Results of Tukey test showed the significant difference between the FL or FT and UF groups(p<0.05). 3. Statistically higher abrasion and surface roughness were observed for the dentifrice of paste type, Perio A+, than for that of gel paste type, Tom & Jerry. 4. The surface roughness values increased on the abraded surfaces because of the protrusion of filler particles due to selective removal of matrix resin.

본 연구에서는 치경부의 심미수복에 이용되고 있는 7종의 재료를 시험재료로 선택한 다음 잇솔질이 이들 수복재료의 마모도에 미치는 영향을 평가하기 위해 전동식 마모시험기를 이용하여 잇솔질 하중 2.0N으로 100,000회의 잇솔질을 시행한 다음 각 시편의 평균 두께 감소와 표면조도를 측정하였고, 표면경도가 연마성 마모에 미치는 영향을 평가하기 위해 누프 경도를 측정한 결과, 다음과 같은 결론을 얻었다. 1. 누프 경도값은 F2000 군에서 79.7로 가장 높고 Heliomolar 군에서 20.0으로 가장 낮은 값을 보였으며, Tukey 다중범위검증법에 의해서 각 군 사이의 통계적 유의성을 검증한 결과 Compoglass 군과 Dyract AP 군을 제외 한 모든 군들 사이에서 상호간에 유의 한 차이를 보였다(p<0.05). 2. 표면조도는 Improved Fuji II LC 군에서 가장 높고 UniFil F군에서 가장 낮게 나타났으며, Tukey 다중범위검증법에 의해서 각 군사이의 통계적 유의성을 검증한 결과, Improved Fuji II LC군, F2000 군과 UniFil F군 사이에서만 상호간에 유의한 차이를 보였다(p<0.05). 3. 표면조도와 마모도는 치약으로 유치용의 겔 형 페이스트인 Tom & Jerry를 사용한 경우보다 성인용의 페이스트인 Perio $A^+$를 사용한 경우에 높게 나타났다(p<0.05). 4. 연마면에서는 기질레진의 선택적인 마모에 의한 필러의 돌출로 인해 표면조도가 증가된 양상이 관찰되었다.

Keywords