Influence of an Aspect Ratio of Rectangular Channel on the Cooling Performance of a Multichip Module

  • Choi, Min-Goo (School of Mechanical Engineering, Sungkyunkwan University) ;
  • Cho, Keum-Nam (School of Mechanical Engineering, Sungkyunkwan University)
  • Published : 2000.03.01

Abstract

Experiments were performed by using PF-5060 and water to investigate the influence of an aspect ratio of a horizontal rectangular channel on the cooling characteristics from an in-line $6{\times}1$ array of discrete heat sources which were flush mounted on the top wall of the channel. The experimental parameters were aspect ratio of rectangular channel, heat flux of simulated VLSI chip, and channel Reynolds number. The chip surface temperatures decreased with the aspect ratio at the first and sixth rows, and decreased more rapidly at a high heat flux than at a low heat flux. The measured friction factors at each aspect ratio for both water and PF-5060 gave a good agreement with the values predicted by the modified Blasius equation within ${\pm}7%$. The Nusselt number increased as the aspect ratio decreased, but the increasing rate of Nusselt number reduced as the aspect ratio decreased. A 5:1 rectangular channel yields the most efficient cooling performance when the heat transfer and pressure drop in the test section were considered simultaneously.

Keywords

References

  1. Choi, M. and Cho, K., 1999, 'Thermal Characteristics of a Multichip Module Using PF -5060 and Water,' KSME Int. J., Vol. 13, No.5, pp. 443-450
  2. Garimella, S. V. and Eibeck, P. A., 1990, 'Heat Transfer Characteristics of an Array of Protruding Elements in Single Phase Forced Convection,' Int. J. Heat Mass Transfer, Vol. 33, No. 12, pp. 2659-2669 https://doi.org/10.1016/0017-9310(90)90202-6
  3. Heindel, T. J., Ramadhyani, S. and Incropera, F. P., 1992, 'Liquid Immersion Cooling of a Longitudinal Array of Discrete Heat Sources in Protruding Substrates: II-Single-phase Convection,' Trans. of the ASME, J. Electronic Packaging, Vol. 114, pp. 55-62
  4. Incropera, F. P., Kerby, J. S., Moffatt, D. F. and Ramadhyani, S., 1986, 'Convection Heat Transfer from Discrete Heat Sources in a Rectangular Channel,' Int. J. Heat Mass Transfer, Vol. 29, pp. 1051-1058 https://doi.org/10.1016/0017-9310(86)90204-8
  5. Jones, Jr, O. C., 1976, 'An Improvement in the Calculation of Turbulent Friction in Rectangular Ducts,' J. Fluid Engineering, Vol. 98, pp. 173 -181
  6. Kostic, M. and Hartnett, J. P., 1986, 'Heat Transfer to Water Flowing Turbulently through a Rectangular Duct with Asymmetric Heating,' Int. J. Heat Mass Transfer, Vol. 29, No.8, pp. 1283 -1291 https://doi.org/10.1016/0017-9310(86)90161-4
  7. Moffat, R. J., 1985, 'Using Uncertainty Analysis in the Planning of and Experiment,' J. Fluid Engineering, Vol. 107, pp. 173-182
  8. Pautsch, G. and Bar-Cohen, A., 1999, 'Thermal Management of Multichip Modules with Evaporative Spray Cooling,' Proceedings of the Pacific Rim/ ASME International and Intersociety Electronic and Photonic Packaging Conference, Hawaii, pp. 1453-1461
  9. Ramaswamy, C., Joshi, Y., Nakayama, W. and Johnson, W. I., 1998, 'Performance of a Compact Two-chamber Two-phase Thermosyphon: Effect of Evaporator Inclination, Liquid Fill Volume and Contact Resistance,' Proceedings of 11 th IHTC, Kyongju, Korea, pp. 127 -132
  10. Sparrow, E. M., Lloyd, J. R. and Hixon, C. W., 1966, 'Experiments on Turbulent Heat Transfer in an Asymmetrically Heated Rectangular Duct,' Trans. of the ASME, J. Heat Transfer, Vol. 88, pp. 170-174
  11. Tan, H. M. and Charters, M. S., 1970, 'An Experimental Investigation of Forced Convective Heat Transfer for Fully-Developed Turbulent Flow in a Rectangular Duct with Asymmetric Heating,' SoL Energy, Vol. 13, pp. 121-125 https://doi.org/10.1016/0038-092X(70)90012-5