Analysis of Noise Source for Mold Transformer

몰드변압기의 소음 원인 분석

  • 최원호 ((주)효성중공업 연구소) ;
  • 김원철 (경상대학교 수송기계공학부(해양산업연구소))
  • Published : 2000.11.30

Abstract

Especially, demands for the noise reduction of mold transformer has been becoming an common issue because it has been used mainly at the residence area such as building and ship. So, this paper investigates the noise source and countermeasure of mold transformer radiated high noise abnormally. The result of impact hammering test for core of transformer ascertains the core resonance by harmonics of line frequency and high noise can be reduced to avoid core resonance by changing torque strength of tie rod. Magnetic field analysis is performed to identify the reason that noise of V-phase is higher than U and W-phase in the normal condition. It is the cause that flux density and magnetic force of V-phase is higher than the other phase respectively.

Keywords