A Study on Characteristic Factors of Tubular Membranes in a Membrane coupled Activated Sludge Process

Tubular형 막을 이용한 활성슬러지법에 있어서 여과특성에 미치는 인자에 관한 연구

  • 박성원 (성균관대학교 토목환경공학과) ;
  • 김형수 (성균관대학교 토목환경공학과) ;
  • 조대철 (LG 환경연구소)
  • Published : 1999.01.15

Abstract

We elucidated factors such as membrane pore size, activity of the activated sludge and MLSS. affecting filtering characteristics or filtering resistance in an activated sludge bio-process using tubular type membranes. We used a commercial membrane module with $0.5m^2$ of effective membrane area and a bundle of 7 tubes(13mm of ID and 2m long) in the experiments. As a result, the flux was maintained in the range of $35{\sim}105l/m^2$ hr at 5,000~20,000mg/l of MLSS concentration, and there seemed to be a correlation between the flux and the MLSS. Also the greater the pores were, the higher the flux was in some comparison experiments using UF and MF membranes, but the water permeated through both of the membranes showed almost the same quality. However, the MF membrane showed a great reduction in filtering resistance initially, but went back to a stable stage afterwards. The activity of the activated sludge in the aeration tank was also found to be considered as a factor showing permeation characteristics of the membrane.

Keywords