A Camera Calibration Algorithm for an Ill-Conditioned Case

악조건하의 카메라 교정을 위한 알고리즘

  • 이정화 (계명대학교 산업공학과 대학원) ;
  • 이문규 (계명대학교 산업공학과)
  • Published : 1999.02.01

Abstract

If the camera plane is nearly parallel to the calibration board on which objects are defined, most of existing calibration approaches such as Tsai's radial-alignment-constraint method cannot be applied. Recently, for such an ill-conditioned case, Zhuang & Wu suggested the linear two-stage calibration algorithm assuming that the exact values of focal length and scale factor are known a priori. In this paper, we developed an iterative two-stage algorithm starts with initial guess fo the two parameters to determine the value of the others using Zhuang & Wu's method. In the second stage, the two parameters are locally optimized. This process is repeated until any improvement cannot be expected any more. The performance comparison between Zhuang & Wu's method and our algorithm shows the superiority of ours. Also included are the computational results for the effects of the distribution and the number of calibration points on the calibration performance.

Keywords