Journal of radiological science and technology (대한방사선기술학회지:방사선기술과학)
- Volume 21 Issue 2
- /
- Pages.11-18
- /
- 1998
- /
- 2288-3509(pISSN)
- /
- 2384-1168(eISSN)
A Experimental Study on Attenuation Rate of Construction Materials in the Diagnostic X-ray Energy
진단 영역의 X-선 에너지에서 각종 건축재료의 감약율 측정실험
- Kim, Jung-Min (Korea University, Health Science College) ;
- Jung, Hoi-Won (Korea University, Kuro Hospital)
- Published : 1998.12.30
Abstract
Single phase, narrow beam X-ray attenuation data were obtained using various construction materials concrete, white block, red block, 3 hole block, gypsum board, artificial marble, cement, plate glass, wood, and lead. Tube voltages of 60, 80, 100, 120 kVp were employed and the resulting curves were compared to transmission data found in this report. The shielding methodology and the derivation of equations used for determination of barrier requirements were presented in NCRP 49. We could calculate the X-ray exposed dose after attenuation and thickness of protection barrier in the clinic facilities accordingly. For the purpose of maximizing the benefit/cost ratio to diagnostic shielding, various construction materials must be installed carefully and attnuation rate considered thoroughly.
Keywords