A Experimental Study on Attenuation Rate of Construction Materials in the Diagnostic X-ray Energy

진단 영역의 X-선 에너지에서 각종 건축재료의 감약율 측정실험

  • 김정민 (고려대학교 보건대학 방사선과) ;
  • 정희원 (고려대학교의료원 구로병원 방사선과)
  • Published : 1998.12.30

Abstract

Single phase, narrow beam X-ray attenuation data were obtained using various construction materials concrete, white block, red block, 3 hole block, gypsum board, artificial marble, cement, plate glass, wood, and lead. Tube voltages of 60, 80, 100, 120 kVp were employed and the resulting curves were compared to transmission data found in this report. The shielding methodology and the derivation of equations used for determination of barrier requirements were presented in NCRP 49. We could calculate the X-ray exposed dose after attenuation and thickness of protection barrier in the clinic facilities accordingly. For the purpose of maximizing the benefit/cost ratio to diagnostic shielding, various construction materials must be installed carefully and attnuation rate considered thoroughly.

Keywords