IN VITRO STUDY ON THE FLUORIDE RELEASE FROM GLASS IONOMER CEMENTS AND A FLUORIDE-CONTAINING RESIN

글라스 아이오노머 시멘트와 불소함유 레진의 불소유리에 관한 연구

  • Kim, Mi-Kyung (Department of Orthodontics, Graduate School, Kyung Hee University) ;
  • Lee, Ki-Soo (Department of Orthodontics, Graduate School, Kyung Hee University)
  • 김미경 (경희대학교 치과대학 치과교정학교실) ;
  • 이기수 (경희대학교 치과대학 치과교정학교실)
  • Published : 1998.06.01

Abstract

In order to resolve enamel demineralization around orthodontic bracket, fluoride-releasing materials, glass ionomer cements and fluoride-containing resin, were introduced in orthodontic department. There were many studies about their fluoride release, but their results were controversial. The purpose of this study was to clarify the pattern and amounts of fluoride release from glass ionomer cements and a fluoride-containing resin during 70 days in vitro. Disc shaped specimens were prepared and immersed in polyethylene tube containing 2ml distilled deionized water. The daily amounts of the fluoride released from each specimens were measured after experiment 1 day, 3 days, 7 days, 14 days, 42 days and 70 days. They were measured by fluoride-specific electrode combined pH/Ion meter. The following results were as follow, 1. Fluorides released from fluoride-containing resin during 1 day were significantly less than those from glass ionomer cements. 2. On experiment 70 days, mean daily amounts of fluoride released from Miracle-$Mix^{\circledR}$were $3.4{\mu}g/cm^2$, those from Fuji GC $II^{\circledR}$ were $2.7{\mu}g/cm^2$, those from $Orthobond^{\circledR}$ were $2.3{\mu}g/cm^2$, those from Fuji GC $LC^{\circledR}$were $1.4{\mu}g/cm^2$ and those from fluoride-containing resin, $Heliomolar^{\circledR}$, were $0.1{\mu}g/cm^2$. 3. There were no significant differences in daily amounts of fluoride released from between self-curing glass ionomer cements and light-curing glass ionomer cements. Amounts of released fluoride varied among commercially available products. 4. In all experimental materials, amounts of released fluoride decreased rapidly until experimental 3 days and then decreased slowly until 14 days and more slowly until 70 days.

불소를 유리하는 치과재료인 글라스 아이오노머 시멘트와 불소함유 레진을 대상으로 경화후의 시간경과에 따른 1일간 불소유리량을 측정하고, 이들의 경시적 변화추세를 비교 검토하기 위하여 광중합형 글라스 아이오노머 시멘트로서 치과교정용 브라켓 접착제($Orthobond^{\circledR}$)와 충전응(Fuji GC $LC^{\circledR}$), 자가중합형 글라스 아이오노머 시멘트로서 충전용 (Fuji GC $II^{\circledR}$)과 아말감 합금이 첨가된 충전용(Miracle-$Mix^{\circledR}$) 및 광중합형 불소함유 충전용 레진($Heliomolar^{\circledR}$)을 실험재료로 하여 중합 1일, 3일, 7일, 14일, 42일, 70일 경과후 각각 불소유리량을 측정하고, 변화추세를 비교 검토하여 다음의 결론을 얻었다. 1. 전 실험기간에 걸쳐 불소함유 레진의 1일간 불소유리량은 글라스 아이포노머 시멘트에 비해 현저히 적었다. 2. 중합 70일 경과후 1일간 불소유리 량은 Miracle-$Mix^{\circledR}$는 평균 $3.4{\mu}g/cm^2$, Fuji GC $II^{\circledR}$가 평균 $2.7{\mu}g/cm^2$, $Orthobond^{\circledR}$가 평균 $2.3{\mu}g/cm^2$, Fuji GC $LC^{\circledR}$이 평균 $1.4{\mu}g/cm^2$였고, 불소함유 레진인 $Heliomolar^{\circledR}$은 평균 $0.1{\mu}g/cm^2$이었다. 3. 1일간 불소유리량은 자가중합형 글라스 아이오노머 시멘트와 광중합형 글라스 아이오노머 시멘트사미에 차이를 발견할 수 없었고, 제조회사의 제품에 따라 유의한 차이가 있었다 아말감 합금이 첨가된 Miracle-$Mix^{\circledR}$은 아말감 합금이 첨가되지 않은 다른 시멘트에 비해 현저히 많은 양의 불소를 유리하였다. 4. 모든 실험재료의 1일간 불소유리 량은 중합 3일이전까지 현저한 감소를 보였고, 중합 3일경과이후 중합 14일 이전까지 완만한 감소를, 중합 14일이후부터 중합 70일경과까지 매우 완만한 감소추세를 보였다.

Keywords