Abstract
Fast spin echo imaging utilizes multiple spin echoes to encode multiple k-space lines instead of multiple $T_2-weighted$ images. As results, intensities in k-space data are varying according to T2 decay, which generates Gibb's artifact in the reconstructed image. The echo time for e encoding dc block determines contrast, as is specified by the effective echo time, however, all location of other echoes to different k-space frequency blocks in fast spin echo imaging is not f fully investigated. In this study, symmetric arrangement of multiple echoes in k-space is investigated to reduce Gibb's artifact. Design of filters based on the measurement of multiple e echo intensities is also proposed in two stage manner, i.e., equalization and filtering. From s simulation and experiment, it was observed that Gibb's phenomena were substantially reduced b by the proposed methods.