Abstract
When steel tube as a column is filled with concrete, it is common that the load-bearing capacities of CFST(Concrete Filled Steel Tube) column are increased substantially, And the CFST column can obtain a capacity of fire resistance without any additional detail on the surface of the steel tube for fire protection. In order to clarify the behavior of CFST column during fire occurrence, a theoretical study is performed, that is, a thermal analysis is used to find temperature gradient dependent on the time on the steel tube and the infilled concrete. N-M (axial force-moment) interaction curves are summarized under the consideration for time dependent variation. The material properties of concrete and steel in accordance with a temperature variation are referred to the existing general data. Thermal transient analyses are performed by finite element method through ANSYS and then these results are verified by comparing with the existing test results. On the basis of analytical results, load-carrying capacities (N-M interaction curves) are calculated by numerical analysis method.
강관에 콘크리트를 충전하는 경우, 콘크리트 충전강관 기둥은 뛰어난 내력과 변형성능을 발휘한다. 그리고 콘크리트의 축열효과에 의해서 일정시간은 내화피복 없이도 내력을 유지할 수 있다. 화재발생동안 콘크리트 충전강관 기둥의 거동을 알아보고자 강관과 콘크리트의 온도에 따른 특성치 변화를 가정하고 온도 해석 및 축력-모멘트관계에 대한 수치해석을 수행하여 시간변화에 따른 변수별로 비교평가하였다. 온도에 따른 특성치는 기존문헌의 데이터를 이용하였으며 온도해석은 범용 해석프로그램인 ANSYS로 유한요소해석을 하였고 이를 바탕으로 내력에 대한 수치해석을 수행하였다.