Abstract
Various type of in-situ and laboratary tests were performed in order to evaluate the stiffness of sedimentary soft rock. In triaxial compression tests of sedimentary soft rocks, axial strains from the axial displacement of the loading piston or specimen cap conventionally were considerably larger than those measured. tocally on the lateral surfaces of specimen, due to the bedding errors at the top and bottom ends of a specimen. A local deformation transducer was used to measure axial strains free from the bedding error ranging from 0.001% to about 1%. In ultra-sonic wave tests, the elastic modulus of unconfined spec imens was smaller than that of confined specimens, due probably to microfracks. Young's modulus Ed from ultra-sonic wave tests and those at small local strains from triaxial tests were similar, both of which agreed very well with Young's modulus Er from field shear wave velocities. Young'a modulus from the field behaviour was virtually similar to that obtained by reducing Er based on the strain level-dependency of stiffness evaluated by the triaxial tests.
퇴적연암의 변형특성을 조사하기 위하여 여러 종류의 실내시험과 원위치시험결과를 비교검토 하였다. 초음파측정시험 등의 실내시험에서 불구속 시료의 탄성계수는 원위치유효토피압에 해당하는 압밀구속압으로 구속한 시료의 탄성계수 보다 현저히 작았다. 또 삼축압축시험에서 재하피 스톤의 축변위로 부터 구한 축변형률은 시료 상.하단에서의 오차(bedding error)로 인하여 정확히 측정할 수 없고, 전체적으로 신뢰할 수 없다. 따라서 시료측면에서 직접 변형률을 측정하는 국소변형측정장치를 이용하여 0.001% 이하에서 약 1%까지 연속적으로 위와 같은 오차를 제거한 축변형률을 얻을 수 있었고, 0.00% 이하 축변형률에서 정의된 탄성계수 Emax는 원위치탄성 파속도시험으로 얻어진 탄성계수 Er와 거의 일치하였다. 변형률이 0.01%에 도달하기 이전에 변형은 비선형성을 보이기 시작하고, 실제 원위치 작용하중 범위에서 예상할 수 있는 최대변형률 0.1%에서의 할선탄성계수 Esec는 Emax의 1/2보다 여전히 큰 값을 보인다. 위와 같은 내용을 골자로 하여 정밀측정실내시험 결과에 따른 변형특성과 현장거동 및 원위치측정결과의 비교검토를 통해 변형률레벨을 고려한 원위치 탄성계수 추정법을 제안하였다.