Abstract
When braced excavation with temporary retaining wall installation, is performed in loose sand with high ground water level boiling may be induced and considerable damage on the excavation works and structures in the vicinity can take place. Recently, for the purpose of reinforcement of ground and cut-off of ground water behind the temporary retaining wall, high pressure jet grouting is widely used. The purpose of this paper is to investigate the effects of jet grouting on ground reinforcement and cut -off of the ground water behind temporary retaining walls for braced excavation. A series of both laboratory and field tests has been performed. The test results show that high pressure jet grouting has sufficient effects on reinforcement of stiffness of ground and retaining wall. The permeability of the improved ground was 10-f_ 10-3cm l s smaller than those of the original ground. Therefore, the effect on cut off of ground water behind temporary retaining walls could be improved by high pressure jet grouting method.
지하수위가 높고 느슨한 사질토지반에서 가설흙막이벽을 설치하여 지하굴착공사를 실시할 경우 굴착저면에서 보일링현상이 발생하여 굴착공사 뿐만 아니라 인접구조물에 상당한 피해를 주게 된다. 따라서 최근에는 흙막이벽 배면지반의 강도를 증대시키면서 동시에 흙막이벽의 차수효과를 높이기 위하여 고압분사주입공법을 실시하여 차수벽을 설치하는 보조공법인 널지 이용되고 있다. 고압분사주입공법에 의해 가설흙막이벽 배면지반에 시공된 지반개량체의 지반보강효과 및 차수효과를 검토하기 위하여 각종 실내시험 및 현장시험을 실시하였다. 시험결과 지반개량체는 지반조건과 시공방법에 따라 약간의 차이는 있으나 충분한 흙막이벽 배면지반의 보강 및 벽체의 강성보강 효과를 얻을 수 있는 것으로 나타났다. 한편 지반개량체의 투수계수는 원지반의 투수 계수보다 10-2~10-3cm/s정도 작아서 흙막이벽의 차수효과를 기대할 수 있는 것으로 나타났다.