A Transient Model Analysis of a Fluorescent Lamp at Startup Time

형광램프의 기동시 과도특성 모델 해석

  • Published : 1996.10.01

Abstract

Fluorescent lamps are widely accepted to energy efficient commercial lighting applications. In designing a fluorescent lamp system, a ballast design heavily relies on the characteristic of a fluorescent lamp under consideration. Especially, at startup time, the transient characteristic of a fluorescent lamp puts much tighter specification of a design. In this paper, based on the transient characteristic at the startup time, a transient behavioral model of a fluorescent lamp is presented with an equivalent circuit. The model is applicable to the wide range of fluorescent lamps provided by different manufacturers. The experimental results are compared with the results provided by PSPICE simulation. The result shows the model is effective In practice. As a result, we could identify more accurate startup constraints to decide the design of either an electro mechanical or an electronic ballast.

형광 램프는 에너지 효율이 높아 상업용 조명설비에 많이 사용된다. 형광램프 시스템의 설계에서 안정기의 설계는 형광 램프의 특성을 고려하는 것이 매우 중요하다. 특히, 시동시 형광램프의 과도특성은 안정기 설계시 좀더 많은 설계사양들을 제공하게 된다. 이 논문에서는 시동시 과도특성에 근거한 형광램프의 동작모델을 동기화로 나타냈다. 이 모델은 제조사가 다른 형광 램프에도 폭 넓게 적용이 가능하다. 실험에 의해 얻어진 결과를 동기회로 모델에 의한 Pspice 시뮬레이션에 의해 나타난 결과와 비교 한 결과, 본 논문에서 제시한 모델이 실질적으로 효용성이 있음을 나타냈으며, 자기식 안정기 및 전기식안정기의 설계시 형광램프의 시동과도특성에 의한 안정기 조건 설계들을 더욱 명확하게 알아낼 수 있었다.

Keywords

References

  1. IEEE-IAS Annual Meeting PSPICE modeling of electronically ballasted compact fluorescent lamp system Yiyoong Sun
  2. IEEE-IAS Annual Meeting Influence of on-time and use frequency on cost effectiveness of compact fluorescent lamps C.R.Suilivan;A.C.Drescher
  3. Journal of the IIIumination Engineering Society v.20 Fluorescent system interaction with electronic ballasts E.E.Hammer
  4. Journal of IES Fluorescent lamp Starting Voltage Relationship at 60[Hz] and High Frequency E.E.Hammer
  5. Fundamentals of Discharge Tube Circuit V.J.Francis
  6. Journal of the IIIumination Engineering Society High Frequency Characteristics of Fluorescent Lamps Up to 500[kHz] E.E.Hammer
  7. ICPE'95 A Transient Modeling of a Fluorescent Lamp at Start-Up Time J.K.Ham;S.Y.Lee;S.H.Baek;K.Y.Lee