Sensor system of flowing cell

세포 흐름 감지 시스템

  • Kwon, Ki-Jin (Department of Electrical Engineering Kyungpook National University) ;
  • Kim, Min-Soo (Department of Electrical Engineering Kyungpook National University) ;
  • Park, Se-Kwang (Department of Electrical Engineering Kyungpook National University)
  • Published : 1995.11.30

Abstract

Sensor system which can detect a flowing cell is designed and fabricated by semiconductor processing and EDM(Electro-chemical Discharge drilling Method). Two methods are used in this paper; 1) optical method which measures the trasmitted light through the cell passage between transmitter and receiver, 2) impedance method which measures impedance change between electrodes, when cell flows in the cell passage. Experimental result using tabaco leaves shows that the ouput value by optical method is 0.2V to 0.7V, and the output by impedance method is 0.2V to 2V, which is bigger, but it includes an avoidable noises.

세포의 흐름을 감지할 수 있는 감지 시스템을 반도체 공정과 EDM(Electro-chemical Discharge drilling Method)을 사용하여 설계 및 제작하였다. 이 감지 장치에서는 세포의 통로관 상하에 광을 투과시켜 감지하는 투과광 방법과 세포 통로관에 평형 전극을 만들어 세포의 흐름에 따른 임피던스의 변화를 측정하는 방법을 사용하였다. 담배잎의 세포를 이용하여 실험한 결과, 광을 이용한 방식에서는 세포의 유무에 따라 출력전압이 0.2V에서 0.7V의 변화를 보였고, 임피던스 방식에서는 0.2V에서 2V의 변화를 감지할 수 있었으나 노이즈의 영향을 받았다.

Keywords