An Evaluation of Reference Values Used for Quality Control of the Korean Industrial Hygiene Laboratory

우리나라 작업환경 측정기관의 정도관리를 위한 기준값에 관한 연구

  • Cheon, Cheong Hwa (Division of Industrial Health, School of Public Health Seoul National University) ;
  • Paik, Nam Won (Division of Industrial Health, School of Public Health Seoul National University)
  • 전정화 (서울대학교 보건대학원 산업보건학교실) ;
  • 백남원 (서울대학교 보건대학원 산업보건학교실)
  • Published : 1994.05.31

Abstract

This study was conducted to evaluate accuracy and precision of reference values used for quality control of the Korean industrial hygiene laboratory for three rounds. Factors affecting on accuracy and precision, including analytical procedures, were investigated. The results are summarized as follows. 1. Pooled relative standard deviation of reference values analyzed by reference laboratories was 2.01-5.91%, and that by both reference laboratories and participated laboratories was 3.18-6.63%. Better results were obtained when results of reference laboratories were employed. 2. Significant relationship was indicated between analytical precision and concentration of materials in samples. Variation increased by decreasing sample concentration. 3. Recoveries of lead and cadmium were about 98.6% and 99.8% respectively. There was a significant difference between lead values with and without recovery correction. 4. Organic solvent results corrected by desorption efficiency only and those corrected by Both internal standards and desorption efficiency were more accurate than those uncorrected. But, the latter was the best.

Keywords