2-유로 카트리지 밸브를 이용한 유압용 유량 센서의 개발
Development of a Flow Rate Sensor Using 2-way Cartridge Valve
- 발행 : 1993.09.01
초록
In this paper the design and test results of a dynamic flow rate sensor was reported. This sensor comprises an 2-way cartridge valve as standard hydraulic component and a displacement sensor. Its working principle bases on the linear relationship between the flow rate and the piston displacement of 2-way cartridge valves under constant pressure drop. This principle is well known, however it is not easy to develop a flow rate sensor with the measurement range of 300 1/min, pressure loss of less than 8 bar at 300 1/min, maximum linearity error of less than