LIQUID PENETRANT TESTING AT LOW TEMPERATURE

저온에서 행하는 액체침투 탐상방법

  • Barbier, R. (FRAMATOME-EXPORT(FRAMEX))
  • Published : 1983.10.31

Abstract

Tests on Liquid Penetrant products normally utilized in the temperature range $10^{\circ}C\;to\;40^{\circ}C$ have shown that the required sensibility can not be obtained at temperatures lower than $10^{\circ}C$ with the penetration and development time usually specified in the operating procedures. It is thus confirmed that $10^{\circ}C$ is the lowest allowable temperature for use of these products. The results obtained with a penetrant and develope. specially formulated for low temperatures (SHERWIN B 305+D100) are satisfactory between $0^{\circ}C\;and\;15^{\circ}C$.