초록
In order to find out the optimum size of nozzle of the power sprayer in the paddy field, four different sized hole of nozzles were tested on its discharge volume per unit time and its effective covering distance. 1. The discharge rate of each nozzle is proportional to square root of the transmitted internal pressure of liquid, and the discharge coefficient ranges from 0.82 to 0.86 at the pressure of 20 to 30 kg/$\textrm{cm}^2$. 2. The effective covering distance is increased as the size of the hole is larded and also the pressure is increased under under the limited pressure. Generally, the effective covering distance is not greatly increased at the pressure of above 25kg/$\textrm{cm}^2$. The distance from the nozzle to the spot where the largest amount of droplets are dropped is about 14.5m for 3.05mm nozzle and 16m for 4.05mm nozzle in the pressure range from 20 to 25kg/$\textrm{cm}^2$. 3. From the above results it is concluded that the 3mm nozzle with the power sprayers, which are now being supplied to the farmers, can be used for disease and insect control on the paddy field of which block size is 30m${\times}$100m, and operators need not to enter the field for spraying. For the 40m${\times}$100m block, 4mm nozzle should be used with large size of pump which discharge capacity is 60l/min or more.