Acknowledgement
본 연구는 국토교통부 건설기술연구사업 (과제번호:21SCIP-B150834-04)의 연구비 지원에 의해 수행되었습니다.
Social infrastructure facilities can be destroyed instantly when exposed to EMP (ElectroMagnetic Pulse), causing social chaos. However, concrete structures with low electrical conductivity cannot expect EMP shielding effect. Therefore, in this study, a metal sprayed thin film showing excellent EMP shielding performance was applied to a concrete structure to evaluate the metal spray welding efficiency and adhesion performance of the thin film according to the concrete surface treatment method. As a result according to the concrete surface treatment method, It was confirmed that the use of a roughening agent that generates physical irregularities in order to improve the welding efficiency and adhesion performance increases the physical performance of the concrete and metal sprayed thin film.
본 연구는 국토교통부 건설기술연구사업 (과제번호:21SCIP-B150834-04)의 연구비 지원에 의해 수행되었습니다.