Proceedings of the Korean Institute of Building Construction Conference (한국건축시공학회:학술대회논문집)
- 2017.11a
- /
- Pages.20-21
- /
- 2017
Pore Structure and Heat of Microhydration Analysis of Blast Furnace Slag Containing Alkaline Activator
알칼리 자극제 혼입 고로슬래그 미분말의 공극구조 및 미소수화열 분석
- Published : 2017.11.16
Abstract
In this study, fundamental properties by pore structure and heat of microhydration test were determined. As a result of pore structure analysis, BS(AA) specimen showed showed the maximum peak value of significantly lower incremental intrusion than the maximum peak value of incremental intrusion at smaller pore size than that of BS. As a result of heat of microhydration test, the maximum heating value was in the order of OPC > BS > BS(AA), and initial drying shrinkage and compressive strength of BS(AA) were expected to be improved.
Keywords