Proceedings of the KIEE Conference (대한전기학회:학술대회논문집)
- 2011.07a
- /
- Pages.1428-1429
- /
- 2011
Variation of Electric Resistance under the CIP process of Strended Copper Conductors
CIP 도체 압축기술에 따른 구리도체 저항변화
- Jeong, Seung (LS Cable & System) ;
- Yang, Hoon-Chul (LS Cable & System) ;
- Choi, Ah-Reum (LS Cable & System)
- Published : 2011.07.20
Abstract
This paper variation of stranded cable conductor with CIP(Cold Isostatic Press) technology. Conductor as cable material takes majority costs. Thus many experiments have been done on conductor compaction. The core technology is to maintain the resistance of circular stranded conductor after compaction process, while reducing the weight of conductor diameter, but by increasing filling factor. Testing by varying the compaction ratio using 300SQ conductor, conductor after CIP process shows lower resistance rather than conductor before CIP process.
Keywords