PC-Slab 합성 철도판형교 유도상화 시험부설에 따른 성능 비교평가

Capacity evaluation of PC-slab composite actions for the railway steel plate girder according to an experimental construction

  • 민경주 ((주)철도안전연구소) ;
  • 이성욱 (한국철도공사 기술본부시설단 토목시설처) ;
  • 최형수 (한국철도공사 연구원 연구팀) ;
  • 우용근 (한국철도공사 경주고속선로관리사업소 고모사업소)
  • 발행 : 2011.05.26

초록

There are more than 800 railway steel plate girder bridges which are in use and the total length is approximately 50 km. Among these, it shall be pointed out that non-ballast rail systems which lay on wood sleepers are the most critical members. To strengthen this type of structures, mainly two methods have been applied. The first one is the most typical method which is to replace the girders with slab girder system or steel composite girders and to add ballast. It is not uncommon that the construction cost of substructure is more than ten time higher than that of superstructures and even in this case, the structural uncertainty for the substructures is not diminished. To resolve above mentioned problems, new method was developed to rehabilitate railway steel girder bridge by adding PC-slab using transport equipment. Using this method, substructure strengthen is rarely required because the additional weight to the bridge superstructure is only up to 1.0t/m. Also it was possible to save the construction cost by reducing construction duration and by simplifying the construction process. Experimental construction was performed for Jewon bridge and measurements were performed before and after construction to verify the bridge capacity.

키워드