Proceedings of the Korean Geotechical Society Conference (한국지반공학회:학술대회논문집)
- 2009.09a
- /
- Pages.1354-1359
- /
- 2009
Ultimate Pullout Capacity of Underreamed Anchors Using Electric Discharge in weathered soil
풍화토지반에서 전기방전에 의한 확공앵커의 극한 인발력
- Kim, Sung-Kyu (Dept. of Civil, Architecture and Environmental System Engineering, SKK Univ.) ;
- Kim, Nak-Kyung (Dept, of Civil Engineering, Univ. of Sungkyunkwan) ;
- Kim, Jae-Won (Dept. of Civil, Architecture and Environmental System Engineering, SKK Univ.) ;
- Kang, Byung-Chul (Dept. of Civil, Architecture and Environmental System Engineering, SKK Univ.) ;
- Kim, Tae-Hun (Daewoo Reserch Institute of Technology)
- 김성규 (성균관대학교 건설환경시스템공학과) ;
- 김낙경 (성균관대학교 건설환경시스템공학과) ;
- 김재원 (성균관대학교 건설환경시스템공학과) ;
- 강병철 (성균관대학교 건설환경시스템공학과) ;
- 김태훈 (대우건설기술연구소)
- Published : 2009.09.25
Abstract
Ground anchor should not be used in soft clay, because anchor resistance can not be guaranteed. However, there is a way to increase the capacity of anchors. The anchor is an underreamed anchor by using high voltage electric discharge energy. In this study, a series of field test were carried out in order to find ultimate load of underreamed anchors in weathered soil at the new apartment construction site located in Inchon, Korea. Data were analyzed in order to define a relation between ultimate load and the number of electric discharge.